Skip to content
Chance Air-Cond Sales & Service

Authorised Daikin dealer · Malaysia

Daikin

Daikin Product Centre

Residential · Commercial · SkyAir · VRV

Compare the official Daikin ranges we supply and install, then ask us which one fits your building. Every figure here is transcribed from Daikin's own brochures, and every series names the document it came from.

Search by Project type · Room · Model number · Series · Category

  • Try

396 model numbers · 21 series · 7 categories · 16 official Daikin brochures

A Daikin wall-mounted unit installed above the window in a bedroom.

Wall Mounted

The standard split unit — one indoor unit high on a wall, one outdoor unit. The most common format in Malaysian homes and small offices.

Specified for: Bedrooms and living rooms; Small offices, clinics and retail lots; Like-for-like replacement on existing pipework.

Energy rating at a glance

Malaysian energy star rating and CSPF for each wall-mounted series, most efficient first.
SeriesEnergy ratingCSPF
FTKH Series — Smarto
5-star
5.75–6.40
FTKM Series
5-star
5.87–7.40
FTKP Series
5-star
5.30–6.00
FTKF Series
4–5 star
4.60–6.00
FTKB Series
4-star
4.50–5.60
FTKE Series
3–4 star
4.20
FTV-P Series
3-star
3.22–3.59
The Daikin FTKH Smarto wall-mounted unit, shown in close-up with its airflow louvre open.

Flagship

FTKH Series — Smarto

Daikin's smart-control wall-mounted range, rated 5-star across every capacity.

Capacity
9,700–19,000 Btu/h
Models
3
Refrigerant
R32
5-starCSPF 5.75–6.40
  • 5 star across the range Every capacity is rated 5 star, at CSPF 6.40 (28 class), 6.31 (35) and 5.75 (50).
  • Gin-ION Blue Filter Tested by the Guangdong Detection Center of Microbiology: 99.94% decomposition of Influenza H1N1 in 2 hours, over 99.99% reduction of Escherichia coli, and no fungus visible under microscope (Grade 0).
  • Smart Control built in Smarto carries Daikin's Smart Control on the indoor unit rather than as an add-on module.
Specifications and model numbers
Model numbers (3)
FTKH Series — Smarto — model numbers with cooling capacity.
Indoor unitOutdoor unitCooling capacity
FTKH28BV1MFRKU28BV1M9,700 (3,700 - 11,600) Btu/h
FTKH35BV1MFRKU35BV1M12,100 (4,000 - 13,000) Btu/h
FTKH50BV1MFRKU50BV1M19,000 (6,000 - 21,200) Btu/h
Full technical specifications
FTKH Series — Smarto — full technical specifications, transcribed from the official Daikin brochure.
SpecificationFTKH28BV1MFFTKH35BV1MFFTKH50BV1MF
Indoor unitFTKH28BV1MFFTKH35BV1MFFTKH50BV1MF
Outdoor unitRKU28BV1MRKU35BV1MRKU50BV1M
Cooling capacity (kW)2.84 (1.08 - 3.40)3.55 (1.17 - 3.81)5.57 (1.76 - 6.21)
Cooling capacity (Btu/h)9,700 (3,700 - 11,600)12,100 (4,000 - 13,000)19,000 (6,000 - 21,200)
CSPF (Wh/Wh)6.406.315.75
Energy rating5 star5 star5 star
Power consumption (W)720 (260 - 1,200)940 (280 - 1,250)1,570 (420 - 2,200)
Running current (A)3.284.206.90
Airflow (cfm)380400430
Indoor sound (dB(A))39 / 27 / 2040 / 28 / 2243 / 33 / 31
Outdoor sound (dB(A))454649
Indoor dimensions H×W×D (mm)288 x 779 x 246288 x 779 x 246288 x 779 x 246
Outdoor dimensions H×W×D (mm)550 x 658 x 273550 x 658 x 273615 x 845 x 300

Control: Daikin Smart Control built into the indoor unit; Wi-Fi operation via the Daikin app.

Official Daikin catalogueDaikin product page

Figures transcribed from Daikin brochure FTKH-0426-M, April 2026, revision M.

The Daikin FTKM wall-mounted indoor unit.

FTKM Series

A 5-star inverter range reaching the highest CSPF on this page — 7.40 at the 25 class — and extending to 7.1 kW, the largest wall-mounted capacity Daikin lists here.

Best for: Bedrooms and living rooms where running cost is the deciding factor

Capacity
8,500–24,200 Btu/h
Models
5
5-starCSPF 5.87–7.40
Specifications and model numbers
CSPF up to 7.40
The 25 class is rated 7.40 Wh/Wh, the highest figure on this page; the range runs 5.87 to 7.40 and every capacity is 5 star.
Five capacities to 7.1 kW
25, 35, 50, 60 and 71 classes — 8,500 to 24,200 Btu/h from a single wall unit.
Coanda airflow
Discharge is turned along the ceiling rather than down at the occupant.
Good Design Award 2021
The brochure records the Malaysia Good Design Award (PSA) 2021 for this series.
  • Large living areas needing more than a 5 kW wall unit
  • Homes wanting Coanda airflow rather than a unit blowing directly down
Model numbers (5)
FTKM Series — model numbers with cooling capacity.
Indoor unitOutdoor unitCooling capacity
FTKM25TVMMRKM25TVMM8,500 (4,100 - 12,300) Btu/h
FTKM35TVMMRKM35TVMM11,900 (4,100 - 14,000) Btu/h
FTKM50TVMMRKM50TVMM17,700 (4,100 - 21,200) Btu/h
FTKM60TVMMRKM60TVMM20,500 (4,100 - 24,200) Btu/h
FTKM71TVMMRKM71TVMM24,200 (4,100 - 28,000) Btu/h
Full technical specifications
FTKM Series — full technical specifications, transcribed from the official Daikin brochure.
SpecificationFTKM25TVMMFTKM35TVMMFTKM50TVMMFTKM60TVMMFTKM71TVMM
Indoor unitFTKM25TVMMFTKM35TVMMFTKM50TVMMFTKM60TVMMFTKM71TVMM
Outdoor unitRKM25TVMMRKM35TVMMRKM50TVMMRKM60TVMMRKM71TVMM
Cooling capacity (kW)2.5 (1.2 - 3.6)3.5 (1.2 - 4.1)5.2 (1.2 - 6.2)6.0 (1.2 - 7.1)7.1 (1.2 - 8.2)
Cooling capacity (Btu/h)8,500 (4,100 - 12,300)11,900 (4,100 - 14,000)17,700 (4,100 - 21,200)20,500 (4,100 - 24,200)24,200 (4,100 - 28,000)
CSPF (Wh/Wh)7.406.536.706.215.87
Energy rating5 star5 star5 star5 star5 star
Power consumption (W)520 (185 - 920)900 (185 - 1,160)1,240 (290 - 1,880)1,520 (290 - 2,230)2,260 (290 - 2,770)
Running current (A)2.604.405.907.2010.50
Airflow (cfm)Not stated in the official Daikin brochure.Not stated in the official Daikin brochure.593657699
Indoor sound (dB(A))42 / 26 / 1943 / 28 / 1945 / 35 / 2948 / 37 / 2949 / 37 / 30

Control: Daikin Mobile Controller as an optional accessory — BRP067A42 for the 25/35 classes, BRP980B42 for 50/60/71. Remote controllers ARC466A51 (25/35) and ARC466A52 (50/60/71).

Official Daikin catalogueDaikin product page

Figures transcribed from Daikin brochure FTKM-0323-D-L, March 2023, revision D.

The Daikin FTKP wall-mounted indoor unit.

FTKP Series

An R32 inverter wall-mounted range rated 5 star across all four capacities, built on a 28-class entry capacity rather than the 25 class the other series use.

Best for: Bedrooms and living rooms

Capacity
9,500–24,000 Btu/h
Models
4
5-starCSPF 5.30–6.00
Specifications and model numbers
5 star across all four capacities
CSPF runs 5.30 at the 28 and 35 classes, 5.60 at the 50 and 6.00 at the 71 — every capacity carries the 5 star label.
28-class entry capacity
The smallest FTKP is a 28 class, which sits between the 25 and 35 classes used across the rest of the wall-mounted line-up.
Wireless or wired on every model
Each capacity ships as an -AV1MF wireless model or an -AV1MW wired model; the machine is identical and only the controller differs.
  • Replacements where the existing unit is a 1.0HP-class 28 rather than a 25
Model numbers (4)
FTKP Series — model numbers with cooling capacity.
Indoor unitOutdoor unitCooling capacity
FTKP28AV1MRKP28AV1M99,500 (3,400 - 11,000) Btu/h
FTKP35AV1MRKP35AV1M12,300 (4,100 - 13,000) Btu/h
FTKP50AV1MRKP50AV1M19,000 (6,000 - 21,200) Btu/h
FTKP71AV1MRKP71AV1M24,000 (6,600 - 24,500) Btu/h
Full technical specifications
FTKP Series — full technical specifications, transcribed from the official Daikin brochure.
SpecificationFTKP28AV1MFTKP35AV1MFTKP50AV1MFTKP71AV1M
Indoor unitFTKP28AV1MFTKP35AV1MFTKP50AV1MFTKP71AV1M
Outdoor unitRKP28AV1M9RKP35AV1MRKP50AV1MRKP71AV1M
Wireless modelFTKP28AV1MFFTKP35AV1MFFTKP50AV1MFFTKP71AV1MF
Wired modelFTKP28AV1MWFTKP35AV1MWFTKP50AV1MWFTKP71AV1MW
Cooling capacity (kW)2.78 (1.00 - 3.22)3.60 (1.20 - 3.81)5.57 (1.76 - 6.21)7.03 (1.93 - 7.18)
Cooling capacity (Btu/h)9,500 (3,400 - 11,000)12,300 (4,100 - 13,000)19,000 (6,000 - 21,200)24,000 (6,600 - 24,500)
CSPF (Wh/Wh)5.305.305.606.00
Energy rating5 star5 star5 star5 star
Power consumption (W)870 (185 - 1,180)1,165 (190 - 1,275)1,590 (420 - 2,200)1,965 (380 - 2,300)
Running current (A)3.93 (1.47 - 5.30)5.24 (1.44 - 5.71)6.99 (2.74 - 9.67)8.61 (2.40 - 10.1)
Airflow (cfm)380400430640
Indoor sound (dB(A))38 / 33 / 26 / 1939 / 34 / 26 / 2142 / 39 / 32 / 2943 / 41 / 36 / 30
Outdoor sound (dB(A))48484952
Indoor dimensions H×W×D (mm)288 x 770 x 246288 x 770 x 246288 x 770 x 246297 x 990 x 288
Outdoor dimensions H×W×D (mm)418 x 695 x 244550 x 675 x 284615 x 845 x 300615 x 845 x 300
Indoor weight (kg)9.09.09.513.0
Outdoor weight (kg)18.021.037.037.0
Official Daikin catalogueDaikin product page

Figures transcribed from Daikin brochure FTKP-0824-F, August 2024, revision F.

The Daikin FTKF wall-mounted indoor unit.

FTKF Series

Daikin's standard R32 inverter wall-mounted range, sold in five capacities from 9,000 to 25,600 Btu/h.

Best for: Bedrooms, living rooms and home offices

Capacity
9,000–25,600 Btu/h
Models
5
4–5 starCSPF 4.60–6.00
Specifications and model numbers
Smart control, in and out of home
A built-in network adaptor (AWM61A01) and the Daikin app allow control from inside or outside the home, with weekly scheduling and statistical energy-usage graphs.
Gin-ION Blue Filter
A silver-ion treated filter that Daikin's brochure states decomposes up to 99.9% of drawn-in viruses in 2 hours, tested by the Guangdong Detection Center of Microbiology.
Low/High Voltage Shield (Super PCB)
Printed circuit boards rated to handle a 150V–440V supply variation, for durability on unstable supply.
Removable drain pan
The drain pan lifts out, which shortens routine cleaning.
  • Small offices, clinics and retail lots
  • Replacing an existing wall-mounted unit on the same pipe route
Model numbers (5)
FTKF Series — model numbers with cooling capacity.
Indoor unitOutdoor unitCooling capacity
FTKF25CV1MRKF25CV1M99,000 (3,400 - 9,200) Btu/h
FTKF35CV1MRKF35CV1M12,300 (4,100 - 13,000) Btu/h
FTKF50CV1MRKF50CV1M18,000 (5,200 - 18,500) Btu/h
FTKF71CV1MRKF71CV1M24,000 (6,600 - 24,500) Btu/h
FTKF75CV1MRKF75CV1M25,600 (7,900 - 29,000) Btu/h
Full technical specifications
FTKF Series — full technical specifications, transcribed from the official Daikin brochure.
SpecificationFTKF25CV1MFTKF35CV1MFTKF50CV1MFTKF71CV1MFTKF75CV1M
Indoor unitFTKF25CV1MFTKF35CV1MFTKF50CV1MFTKF71CV1MFTKF75CV1M
Outdoor unitRKF25CV1M9RKF35CV1MRKF50CV1MRKF71CV1MRKF75CV1M
Wireless modelFTKF25CV1MFFTKF35CV1MFFTKF50CV1MFFTKF71CV1MFFTKF75CV1MF
Wired modelFTKF25CV1MWFTKF35CV1MWFTKF50CV1MWFTKF71CV1MWNot stated in the official Daikin brochure.
Cooling capacity (kW)2.64 (1.00 - 2.70)3.60 (1.20 - 3.81)5.28 (1.52 - 5.42)7.03 (1.93 - 7.18)7.50 (2.32 - 8.50)
Cooling capacity (Btu/h)9,000 (3,400 - 9,200)12,300 (4,100 - 13,000)18,000 (5,200 - 18,500)24,000 (6,600 - 24,500)25,600 (7,900 - 29,000)
CSPF (Wh/Wh)4.604.605.026.005.60
Energy rating4 star5 starNot stated in the official Daikin brochure.Not stated in the official Daikin brochure.Not stated in the official Daikin brochure.
Power consumption (W)860 (200 - 960)1,175 (200 - 1,285)1,880 (380 - 1,950)1,965 (380 - 2,300)2,180 (520 - 2,580)
Running current (A)3.875.278.248.619.71
Airflow (cfm)340400430640700
Indoor sound (dB(A))39 / 33 / 26 / 2139 / 34 / 26 / 2142 / 39 / 32 / 2943 / 41 / 36 / 3044 / 41 / 36 / 30
Outdoor sound (dB(A))48485253Not stated in the official Daikin brochure.
Indoor dimensions H×W×D (mm)280 x 730 x 213288 x 770 x 234297 x 990 x 273297 x 990 x 273297 x 990 x 273
Outdoor dimensions H×W×D (mm)418 x 695 x 244550 x 675 x 284615 x 845 x 300695 x 930 x 350Not stated in the official Daikin brochure.
Indoor weight (kg)8.59.09.513.013.0
Outdoor weight (kg)18.021.033.037.040.0

Control: Wireless models ship with a wireless remote (ARC486A1) and a built-in network adaptor (AWM61A01) for the Daikin app. Wired models ship with the SHIRO wired controller (BRC51D61); app control on a wired model additionally requires the optional NS Splitter (R50044157819).

Official Daikin catalogueDaikin product page

Figures transcribed from Daikin brochure FTKF-0824-J, August 2024, revision J.

The Daikin FTKB wall-mounted indoor unit.

FTKB Series

An R32 inverter wall-mounted range in five capacities from 9,000 to 25,600 Btu/h.

Best for: Bedrooms and living areas where running cost is the deciding factor

Capacity
9,000–25,600 Btu/h
Models
5
4-starCSPF 4.50–5.60
Specifications and model numbers
CSPF up to 4.90
The 25 and 35 classes are rated 4.90 Wh/Wh, ahead of the 4.60 recorded for the equivalent FTKF capacities.
R32 refrigerant
Lower global warming potential than R410A and a single-component refrigerant, so it can be topped up rather than fully recovered and recharged.
  • Homes replacing older non-inverter units
  • Small commercial spaces on a single-split layout
Model numbers (5)
FTKB Series — model numbers with cooling capacity.
Indoor unitOutdoor unitCooling capacity
FTKB25AV1MRKB25AV1M9,000 (3,500 - 9,200) Btu/h
FTKB35AV1MRKB35AV1M12,300 (4,100 - 12,800) Btu/h
FTKB50AV1MRKB50AV1M18,000 (5,600 - 18,500) Btu/h
FTKB71AV1MRKB71AV1M24,000 (6,600 - 24,500) Btu/h
FTKB75AV1MRKB75AV1M25,600 (7,900 - 29,000) Btu/h
Full technical specifications
FTKB Series — full technical specifications, transcribed from the official Daikin brochure.
SpecificationFTKB25AV1MFTKB35AV1MFTKB50AV1MFTKB71AV1MFTKB75AV1M
Indoor unitFTKB25AV1MFTKB35AV1MFTKB50AV1MFTKB71AV1MFTKB75AV1M
Outdoor unitRKB25AV1MRKB35AV1MRKB50AV1MRKB71AV1MRKB75AV1M
Cooling capacity (kW)2.64 (1.03 - 2.70)3.60 (1.20 - 3.75)5.28 (1.64 - 5.42)7.03 (1.93 - 7.18)7.50 (2.32 - 8.50)
Cooling capacity (Btu/h)9,000 (3,500 - 9,200)12,300 (4,100 - 12,800)18,000 (5,600 - 18,500)24,000 (6,600 - 24,500)25,600 (7,900 - 29,000)
CSPF (Wh/Wh)4.904.904.574.505.60
Energy rating4 star4 starNot stated in the official Daikin brochure.Not stated in the official Daikin brochure.Not stated in the official Daikin brochure.
Power consumption (W)890 (255 - 960)1,160 (250 - 1,240)1,650 (420 - 1,700)2,160 (380 - 2,300)2,180 (520 - 2,580)
Running current (A)3.96 (2.08 - 4.28)5.50 (2.37 - 5.88)7.29 (2.41 - 7.52)9.49 (2.40 - 10.1)9.71 (2.56 - 11.4)
Airflow (cfm)340400430640700
Indoor sound (dB(A))39 / 33 / 26 / 2140 / 35 / 28 / 2342 / 39 / 32 / 2943 / 41 / 36 / 3044 / 41 / 36 / 30
Outdoor sound (dB(A))4849525353
Indoor dimensions H×W×D (mm)280 x 730 x 213288 x 770 x 234297 x 990 x 273297 x 990 x 273297 x 990 x 273
Outdoor dimensions H×W×D (mm)460 x 650 x 240550 x 675 x 284615 x 845 x 300695 x 930 x 350695 x 930 x 350
Indoor weight (kg)8.09.09.513.013.0
Official Daikin catalogueDaikin product page

Figures transcribed from Daikin brochure FTKB-1225-A, December 2025, revision A.

The Daikin FTKE wall-mounted indoor unit.

FTKE Series

An R32 inverter wall-mounted range covering 9,000 to 24,000 Btu/h across four capacities, at a consistent CSPF of 4.20.

Best for: Bedrooms and living rooms

Capacity
9,000–24,000 Btu/h
Models
4
3–4 starCSPF 4.20
Specifications and model numbers
One efficiency figure across the range
All four capacities are rated CSPF 4.20, which simplifies specification when a project needs several different sizes.
R32 refrigerant
Single-component refrigerant with lower global warming potential than R410A.
  • Straightforward residential replacements
  • Projects specifying one series across mixed room sizes
Model numbers (4)
FTKE Series — model numbers with cooling capacity.
Indoor unitOutdoor unitCooling capacity
FTKE25AV1MRKE25AV1M9,000 (3,500 - 9,200) Btu/h
FTKE35AV1MRKE35AV1M12,300 (4,100 - 12,800) Btu/h
FTKE50AV1MRKE50AV1M18,000 (5,200 - 18,500) Btu/h
FTKE71AV1MRKE71AV1M24,000 (6,600 - 24,500) Btu/h
Full technical specifications
FTKE Series — full technical specifications, transcribed from the official Daikin brochure.
SpecificationFTKE25AV1MFTKE35AV1MFTKE50AV1MFTKE71AV1M
Indoor unitFTKE25AV1MFTKE35AV1MFTKE50AV1MFTKE71AV1M
Outdoor unitRKE25AV1MRKE35AV1MRKE50AV1MRKE71AV1M
Wireless modelFTKE25AV1MFFTKE35AV1MFFTKE50AV1MFFTKE71AV1MF
Wired modelFTKE25AV1MWFTKE35AV1MWFTKE50AV1MWFTKE71AV1MW
Cooling capacity (kW)2.64 (1.03 - 2.70)3.60 (1.20 - 3.75)5.28 (1.52 - 5.42)7.03 (1.93 - 7.18)
Cooling capacity (Btu/h)9,000 (3,500 - 9,200)12,300 (4,100 - 12,800)18,000 (5,200 - 18,500)24,000 (6,600 - 24,500)
CSPF (Wh/Wh)4.204.204.204.20
Energy rating3 star3 star4 star4 star
Power consumption (W)890 (255 - 980)1,245 (255 - 1,330)2,130 (380 - 2,180)2,160 (380 - 2,300)
Running current (A)4.00 (1.65 - 4.39)5.52 (1.75 - 5.88)9.34 (2.72 - 9.54)9.49 (2.40 - 10.1)
Airflow (cfm)340350430640
Indoor sound (dB(A))39 / 33 / 26 / 2140 / 35 / 28 / 2342 / 39 / 32 / 2943 / 41 / 36 / 30
Outdoor sound (dB(A))4852Not stated in the official Daikin brochure.Not stated in the official Daikin brochure.
Indoor dimensions H×W×D (mm)280 x 730 x 213288 x 770 x 234297 x 990 x 273297 x 990 x 273
Indoor weight (kg)8.08.59.513.0
Official Daikin catalogueDaikin product page

Figures transcribed from Daikin brochure FTKE-0724-A, July 2024, revision A.

The Daikin FTV-P wall-mounted indoor unit.

FTV-P Series

Daikin's R32 non-inverter wall-mounted range, in five capacities from 9,500 to 30,000 Btu/h.

Best for: Rooms used in short bursts rather than continuously

Capacity
9,500–30,000 Btu/h
Models
5
3-starCSPF 3.22–3.59
Specifications and model numbers
Largest capacity in the wall-mounted line-up
The FTV85 class delivers 30,000 Btu/h — above the 25,600 Btu/h ceiling of the inverter wall-mounted series in this catalogue.
Fixed-speed operation
The compressor runs at one output. Where a room is occupied intermittently, this avoids paying an inverter premium that longer run hours would be needed to recover.
  • Rental units and back-of-house areas
  • Budget-led replacements where inverter payback does not apply
Model numbers (5)
FTV-P Series — model numbers with cooling capacity.
Indoor unitOutdoor unitCooling capacity
FTV28PBV1MRV28PBV1M99,500 Btu/h
FTV35PBV1MRV35PBV1M912,000 Btu/h
FTV50PBV1MRV50PBV1M18,000 Btu/h
FTV60PBV1MRV60PBV1M22,500 Btu/h
FTV85PBV1MRC85BV1M30,000 Btu/h
Full technical specifications
FTV-P Series — full technical specifications, transcribed from the official Daikin brochure.
SpecificationFTV28PBV1MFTV35PBV1MFTV50PBV1MFTV60PBV1MFTV85PBV1M
Indoor unitFTV28PBV1MFTV35PBV1MFTV50PBV1MFTV60PBV1MFTV85PBV1M
Outdoor unitRV28PBV1M9RV35PBV1M9RV50PBV1MRV60PBV1MRC85BV1M
Wireless modelFTV28PBV1MF9FTV35PBV1MF9FTV50PBV1MFFTV60PBV1MFFTV85PBV1MF
Wired modelFTV28PBV1MW9FTV35PBV1MW9FTV50PBV1MWFTV60PBV1MWFTV85PBV1MW
Cooling capacity (kW)2.783.525.286.598.79
Cooling capacity (Btu/h)9,50012,00018,00022,50030,000
CSPF (Wh/Wh)3.423.593.373.223.28
Energy rating3 star3 star3 star3 star3 star
Power consumption (W)8651,0401,6602,1302,900
Running current (A)3.864.617.3813.109.52
Airflow (cfm)342355531931614
Indoor sound (dB(A))37 / 33 / 27 / 2539 / 35 / 29 / 2842 / 39 / 36 / 3551 / 46 / 42 / 3946 / 43 / 39 / 37
Outdoor sound (dB(A))4648525452
Indoor dimensions H×W×D (mm)288 x 800 x 212288 x 800 x 212310 x 1,065 x 228310 x 1,065 x 228310 x 1,289 x 240
Outdoor dimensions H×W×D (mm)Not stated in the official Daikin brochure.Not stated in the official Daikin brochure.550 x 658 x 273615 x 845 x 300695 x 930 x 350
Indoor weight (kg)9.09.014.016.016.0
Outdoor weight (kg)2828404653
Official Daikin catalogueDaikin product page

Figures transcribed from Daikin brochure FTV-0724-T, July 2024, revision T.

Send us the room and the ceiling. We will size it and name the model.

Get a recommendation
A Daikin multi-split system diagram: one outdoor unit connected to three wall units and two ducted units.

Multi Split

Several indoor units on one outdoor unit. Specified where only one condenser position exists or where building management limits the number of outdoor units.

Specified for: Apartments and condominiums with a single condenser ledge; Terraced homes serving several bedrooms from one plant location.

A Daikin FTKM multi-split indoor unit.

MKM Series — Multi-Split (DC Inverter)

DC inverter multi-split: two to five FTKM indoor units on one MKM outdoor unit.

Compressor
Inverter
Refrigerant
Capacity
Energy rating
Models
6
Best for
Apartments and terraced homes with one usable condenser position
Specifications and model numbers
695 mm lowline outdoor units
The 6.5 and 8.0 kW classes clear a 720 mm window opening, which matters when a condenser has to be carried through an apartment.
60–80 m total piping length
Maximum total piping run of 60 to 80 m with a 15 m level difference, which gives freedom in placing indoor units far from the plant position.
One outdoor unit, several rooms
Multiple indoor units on one refrigerant circuit — the reason this format is specified where roof or ledge space allows only one condenser.
Model numbers (6)
MKM Series — Multi-Split (DC Inverter) — model numbers with cooling capacity.
Indoor unitOutdoor unitCooling capacity
FTKM25PVMMKM65PVM / MKM80PVM / MKM95PVM / MKM105PVMClass 25 — kW figure not stated in the official Daikin brochure.
FTKM35PVMMKM65PVM / MKM80PVM / MKM95PVM / MKM105PVMClass 35 — kW figure not stated in the official Daikin brochure.
FTKM42PVMMKM65PVM / MKM80PVM / MKM95PVM / MKM105PVMClass 42 — kW figure not stated in the official Daikin brochure.
FTKM50PVMMKM65PVM / MKM80PVM / MKM95PVM / MKM105PVMClass 50 — kW figure not stated in the official Daikin brochure.
FTKM60PVMMKM80PVM / MKM95PVM / MKM105PVMClass 60 — kW figure not stated in the official Daikin brochure.
FTKM71PVMMKM95PVM / MKM105PVMClass 71 — kW figure not stated in the official Daikin brochure.
Official Daikin catalogueDaikin product page

Figures transcribed from Daikin brochure MKM-0520-C, May 2020, revision C.

A Daikin CTKC multi-split indoor unit.

MKC Series — Multi-Split

A multi-split range pairing CTKC indoor units with one MKC outdoor unit, in two outdoor classes.

Compressor
Non-Inverter
Refrigerant
R32
Capacity
Energy rating
Models
3
Best for
Apartments and condominiums with one usable condenser position
Specifications and model numbers
Two outdoor classes
MKC50RVM at 5.0 kW rated cooling (8.5 kW maximum connected indoor capacity) and MKC70SVM at 7.0 kW (12.0 kW maximum).
Power-Airflow Dual Flap on the 50 class
The brochure records the Dual Flap on CTKC50SVM and the single Power-Airflow Flap on CTKC25/35RVM.
Standby electricity saving
Reduces the standby power an idle indoor unit draws, per the brochure's function list.
Model numbers (3)
MKC Series — Multi-Split — model numbers with cooling capacity.
Indoor unitOutdoor unitCooling capacity
CTKC25RVMMKC50RVM / MKC70SVM2.5 kW class
CTKC35RVMMKC50RVM / MKC70SVM3.5 kW class
CTKC50SVMMKC70SVM5.0 kW class
Official Daikin catalogueDaikin product page

Figures transcribed from Daikin brochure MKC-0520-C, May 2020, revision C.

Send us the room and the ceiling. We will size it and name the model.

Get a recommendation
Daikin's Premium Black REVO cassette shown in a café interior.

SkyAir Cassette

Ceiling-recessed units that discharge across the ceiling plane. Chosen where a wall unit would be visually intrusive or where distribution from a central point suits the room.

Specified for: Restaurants, cafés and retail floors; Offices, meeting rooms and clinics on a suspended ceiling.

The Daikin REVO Max surround cassette with its Premium Black decoration panel.

Flagship

FCFG Series — REVO Max Surround Cassette

Daikin's flagship R32 inverter surround-flow cassette, in seven capacities from 18,500 to 48,000 Btu/h.

Capacity
18,500–48,000 Btu/h
Models
7
Refrigerant
R32
  • Premium White or Premium Black panel BCR50GMF (white) or BCR50GMFK (black) fits every capacity in the range. The unit is identical; only the visible panel changes.
  • Surround airflow Discharge around the full perimeter of the panel rather than from four fixed louvres, which evens out distribution beneath the unit.
  • Built-in drain pump A water pump is fitted as standard, which gives freedom in routing the condensate drain rather than constraining the unit position to the fall available.
Specifications and model numbers
Model numbers (7)
FCFG Series — REVO Max Surround Cassette — model numbers with cooling capacity.
Indoor unitOutdoor unitCooling capacity
FCFG50AV1MF9RZFG50AGVMM18,500 (7,800-19,100) Btu/h
FCFG60AV1MF9RZFG60AGVMM20,500 (8,900-21,500) Btu/h
FCFG71AV1MF9RZFG71AGVMM24,200 (10,900-27,300) Btu/h
FCFG85AV1MF9RZFG85AVMM30,000 (14,300-34,100) Btu/h
FCFG100AV1MFRZFG100AVMM36,000 (17,100-38,200) Btu/h
FCFG125AV1MFRZFG125AY1M42,000 (19,500-47,800) Btu/h
FCFG140AV1MFRZFG140AY1M48,000 (21,200-52,900) Btu/h
Full technical specifications
FCFG Series — REVO Max Surround Cassette — full technical specifications, transcribed from the official Daikin brochure.
SpecificationFCFG50AV1MF9FCFG60AV1MF9FCFG71AV1MF9FCFG85AV1MF9FCFG100AV1MFFCFG125AV1MFFCFG140AV1MF
Indoor unitFCFG50AV1MF9FCFG60AV1MF9FCFG71AV1MF9FCFG85AV1MF9FCFG100AV1MFFCFG125AV1MFFCFG140AV1MF
Outdoor unitRZFG50AGVMMRZFG60AGVMMRZFG71AGVMMRZFG85AVMMRZFG100AVMMRZFG125AY1MRZFG140AY1M
Cooling capacity (kW)5.42 (2.30-5.60)6.00 (2.30-6.30)7.10 (3.20-8.00)8.79 (4.20-10.00)10.55 (5.00-11.20)12.31 (5.70-14.00)14.07 (6.20-15.50)
Cooling capacity (Btu/h)18,500 (7,800-19,100)20,500 (8,900-21,500)24,200 (10,900-27,300)30,000 (14,300-34,100)36,000 (17,100-38,200)42,000 (19,500-47,800)48,000 (21,200-52,900)
CSPF (Wh/Wh)4.474.344.784.674.684.294.10
Power consumption (W)1,6801,9602,0702,7103,4704,2155,455
Running current (A)7.378.559.0712.015.36.488.38
Airflow (cfm)855 / 715 / 595 / 470855 / 715 / 595 / 470855 / 715 / 595 / 470855 / 715 / 595 / 4701,075 / 960 / 830 / 7201,075 / 960 / 830 / 7201,075 / 960 / 830 / 720
Indoor sound (dB(A))44 / 40 / 37 / 3444 / 40 / 37 / 3444 / 40 / 37 / 3544 / 40 / 37 / 3548 / 46 / 43 / 4048 / 46 / 43 / 4048 / 46 / 43 / 40
Outdoor sound (dB(A))52525253545456
Indoor dimensions H×W×D (mm)246 x 840 x 840 (panel 135 x 962 x 962)246 x 840 x 840 (panel 135 x 962 x 962)246 x 840 x 840 (panel 135 x 962 x 962)246 x 840 x 840 (panel 135 x 962 x 962)288 x 840 x 840 (panel 135 x 962 x 962)288 x 840 x 840 (panel 135 x 962 x 962)288 x 840 x 840 (panel 135 x 962 x 962)
Outdoor dimensions H×W×D (mm)615 x 845 x 300615 x 845 x 300615 x 845 x 300695 x 930 x 350695 x 930 x 350990 x 940 x 320990 x 940 x 320
Indoor weight (kg)22.0 (panel 8.5)22.0 (panel 8.5)22.0 (panel 8.5)22.0 (panel 8.5)25.0 (panel 8.5)25.0 (panel 8.5)25.0 (panel 8.5)
Outdoor weight (kg)37.037.037.040.040.062.062.0

Control: Wi-Fi control is available and, per the brochure, is compatible with the DAMA app only. Wireless remote is standard; BRC-series wired controllers are listed as optional.

Official Daikin catalogueDaikin product page

Figures transcribed from Daikin brochure FCFG-0825-E, August 2025, revision E.

The Daikin FCFC A-Series inverter ceiling cassette, underside view.

FCFC A-Series — Inverter Ceiling Cassette

Daikin's R32 inverter ceiling cassette, in seven capacities from 18,500 to 48,000 Btu/h with 8-way airflow.

Best for: Offices, retail floors and restaurants on a suspended ceiling

Capacity
18,500–48,000 Btu/h
Models
7
Specifications and model numbers
8-way airflow
Discharge in eight directions rather than four, which the brochure records as giving even distribution and faster pull-down.
CSPF up to 4.78
The 71 class is rated 4.78 Wh/Wh; the range runs from 4.10 at the 140 class to 4.78.
Auto-restart with surge protection
After a power failure the unit restarts to its last settings, with 64 recovery patterns staggered to avoid a simultaneous surge.
Selectable external static pressure
Two ESP settings selected by a connector inside the control box, so the same unit suits different duct designs.
  • Rooms needing even distribution from one central ceiling position
  • Projects standardising cassette and ducted indoor types on one outdoor range
Model numbers (7)
FCFC A-Series — Inverter Ceiling Cassette — model numbers with cooling capacity.
Indoor unitOutdoor unitCooling capacity
FCFC50AV1MFRZFC50AGVMM18,500 (7,800-19,100) Btu/h
FCFC60AV1MFRZFC60AGVMM20,500 (8,900-21,500) Btu/h
FCFC71AV1MFRZFC71AGVMM24,200 (10,900-27,300) Btu/h
FCFC85AV1MFRZFC85AVMM30,000 (14,300-34,100) Btu/h
FCFC100AV1MFRZFC100AVMM36,000 (17,100-38,200) Btu/h
FCFC125AV1MFRZFC125AY1M42,000 (19,500-47,800) Btu/h
FCFC140AV1MFRZFC140AY1M48,000 (21,200-52,900) Btu/h
Full technical specifications
FCFC A-Series — Inverter Ceiling Cassette — full technical specifications, transcribed from the official Daikin brochure.
SpecificationFCFC50AV1MFFCFC60AV1MFFCFC71AV1MFFCFC85AV1MFFCFC100AV1MFFCFC125AV1MFFCFC140AV1MF
Indoor unitFCFC50AV1MFFCFC60AV1MFFCFC71AV1MFFCFC85AV1MFFCFC100AV1MFFCFC125AV1MFFCFC140AV1MF
Outdoor unitRZFC50AGVMMRZFC60AGVMMRZFC71AGVMMRZFC85AVMMRZFC100AVMMRZFC125AY1MRZFC140AY1M
Wireless modelBCR50FMF panelBCR50FMF panelBCR50FMF panelBCR50FMF panelBCR50FMF panelBCR50FMF panelBCR50FMF panel
Wired modelBCR50FMW panelBCR50FMW panelBCR50FMW panelBCR50FMW panelBCR50FMW panelBCR50FMW panelBCR50FMW panel
Cooling capacity (kW)5.42 (2.30-5.60)6.00 (2.60-6.30)7.10 (3.20-8.00)8.79 (4.20-10.00)10.55 (5.00-11.20)12.31 (5.70-14.00)14.07 (6.20-15.50)
Cooling capacity (Btu/h)18,500 (7,800-19,100)20,500 (8,900-21,500)24,200 (10,900-27,300)30,000 (14,300-34,100)36,000 (17,100-38,200)42,000 (19,500-47,800)48,000 (21,200-52,900)
CSPF (Wh/Wh)4.474.344.784.674.684.294.10
Power consumption (W)1,6801,9602,0702,7103,4704,2155,455
Running current (A)7.378.559.0712.0015.306.488.38
Airflow (cfm)890 / 760 / 620 / 490890 / 760 / 620 / 490890 / 760 / 620 / 490890 / 760 / 620 / 4901,120 / 1,030 / 890 / 7601,120 / 1,030 / 890 / 7601,120 / 1,030 / 890 / 760
Indoor sound (dB(A))44 / 40 / 37 / 3544 / 40 / 37 / 3544 / 40 / 37 / 3544 / 40 / 37 / 3548 / 46 / 43 / 4048 / 46 / 43 / 4048 / 46 / 43 / 40
Outdoor sound (dB(A))52525253545456
Indoor dimensions H×W×D (mm)246 x 840 x 840 (with panel 305 x 950 x 950)246 x 840 x 840 (with panel 305 x 950 x 950)246 x 840 x 840 (with panel 305 x 950 x 950)246 x 840 x 840 (with panel 305 x 950 x 950)288 x 840 x 840 (with panel 347 x 950 x 950)288 x 840 x 840 (with panel 347 x 950 x 950)288 x 840 x 840 (with panel 347 x 950 x 950)
Outdoor dimensions H×W×D (mm)615 x 845 x 300615 x 845 x 300615 x 845 x 300695 x 930 x 350695 x 930 x 350990 x 940 x 320990 x 940 x 320
Indoor weight (kg)22 (with panel 27)22 (with panel 27)22 (with panel 27)22 (with panel 27)25 (with panel 30)25 (with panel 30)25 (with panel 30)
Outdoor weight (kg)37373740Not stated in the official Daikin brochure.Not stated in the official Daikin brochure.Not stated in the official Daikin brochure.

Control: Wireless or wired decoration panel variants (BCR50FMF / BCR50FMW). The brochure lists a weekly timer on the wired controller and an indoor-unit ON/OFF button on the unit itself.

Official Daikin catalogueDaikin product page

Figures transcribed from Daikin brochure RC-0921-H, September 2021, revision H.

The Daikin FCC A-Series ceiling cassette, underside view.

FCC-A Series — Ceiling Cassette

SkyAir inverter ceiling cassettes listed in the single-split catalogue, sharing the RC/RZFC outdoor range with the ducted FDMFC series.

Best for: Offices, shops and clinics on a suspended ceiling

Models
6
Specifications and model numbers
Shares the SkyAir outdoor range
Cassette and ducted indoor units draw on the same RC/RZFC outdoor units, which simplifies spares and service across a mixed installation.
  • Projects standardising on one SkyAir outdoor range across cassette and ducted indoor types
Model numbers (6)
FCC-A Series — Ceiling Cassette — model numbers with cooling capacity.
Indoor unitOutdoor unitCooling capacity
FCC50AV1M8RC50BV1MNot stated in the official Daikin brochure.
FCC60AV1M8RC60BV1MNot stated in the official Daikin brochure.
FCC85AV1M8RC85BV1MNot stated in the official Daikin brochure.
FCC100AV1M8RC100BV1MNot stated in the official Daikin brochure.
FCC125AV1M8RC125BY1MNot stated in the official Daikin brochure.
FCC140AV1M8RC140BY1MNot stated in the official Daikin brochure.
Official Daikin catalogueDaikin product page

Figures transcribed from Daikin brochure RC-0921-H, September 2021, revision H.

The Daikin FCFV REVO surround cassette in white.

FCFV Series — Ceiling Cassette (Non-Inverter)

SkyAir non-inverter ceiling cassettes, listed across eleven capacity classes with matching RGFV outdoor units.

Best for: Function rooms, halls and premises with scheduled operating hours

Models
11
Specifications and model numbers
Eleven capacity classes
From class 18 to class 125, which is the widest class spread of any single cassette series in this catalogue set.
  • Budget-led commercial fit-outs where inverter payback does not apply
Model numbers (11)
FCFV Series — Ceiling Cassette (Non-Inverter) — model numbers with cooling capacity.
Indoor unitOutdoor unitCooling capacity
FCFV18AV1SRGFV18AV1SClass 18 — kW figure not stated in the official Daikin brochure.
FCFV24AV1SRGFV24AV1SClass 24 — kW figure not stated in the official Daikin brochure.
FCFV30AV1SRGFV30AV1SClass 30 — kW figure not stated in the official Daikin brochure.
FCFV36AV1SRGFV36AV1SClass 36 — kW figure not stated in the official Daikin brochure.
FCFV42AV1SRGFV42AY1SClass 42 — kW figure not stated in the official Daikin brochure.
FCFV46AV1SRGFV46AY1SClass 46 — kW figure not stated in the official Daikin brochure.
FCFV50AV1MFRGFV50AV1MClass 50 — kW figure not stated in the official Daikin brochure.
FCFV60AV1MFRGFV60AV1MClass 60 — kW figure not stated in the official Daikin brochure.
FCFV85AV1MFRGFV85AV1MClass 85 — kW figure not stated in the official Daikin brochure.
FCFV100AV1MFRGFV100AV1MClass 100 — kW figure not stated in the official Daikin brochure.
FCFV125AV1MFRGFV125AY1MClass 125 — kW figure not stated in the official Daikin brochure.
Official Daikin catalogueDaikin product page

Figures transcribed from Daikin brochure FCFV-1221-A, December 2021, revision A.

Send us the room and the ceiling. We will size it and name the model.

Get a recommendation
Linear supply grilles in the ceiling of a boardroom, the ducted units concealed above.

Ceiling Concealed Duct

The unit sits inside the ceiling void and delivers through ductwork to grilles. Nothing of the equipment is visible in the finished room.

Specified for: Designer-led interiors where the ceiling is resolved; Premium residential and hotel rooms; One unit serving several small rooms through ductwork.

The Daikin FDMFC-A ceiling concealed ducted unit.

FDMFC-A Series — Ceiling Concealed Duct

R32 inverter ducted units that sit entirely inside the ceiling void, with supply and return through grilles.

Compressor
Inverter
Refrigerant
R32
Capacity
18,500–48,000 Btu/h
Energy rating
Models
7
Best for
Rooms where nothing should be visible but the grilles
Specifications and model numbers
Nothing visible but the grilles
The unit sits above the ceiling. Where a designer has resolved the ceiling, this is the format that does not interrupt it.
30/50 Pa external static pressure
Standard and high settings are both listed, which determines how far ductwork can be run and how many outlets one unit can feed.
CSPF up to 4.76
The 85 class is rated 4.76 Wh/Wh.
Model numbers (7)
FDMFC-A Series — Ceiling Concealed Duct — model numbers with cooling capacity.
Indoor unitOutdoor unitCooling capacity
FDMFC50AV1MRZFC50AGVMM18,500 (7,800-19,100) Btu/h
FDMFC60AV1MRZFC60AGVMM20,500 (8,900-21,500) Btu/h
FDMFC71AV1MRZFC71AGVMM24,200 (10,900-27,300) Btu/h
FDMFC85AV1MRZFC85AVMM30,000 (14,300-34,100) Btu/h
FDMFC100AV1MRZFC100AVMM36,000 (17,100-38,200) Btu/h
FDMFC125AV1MRZFC125AY1M42,000 (19,500-47,800) Btu/h
FDMFC140AV1MRZFC140AY1M48,000 (21,200-52,900) Btu/h
Full technical specifications
FDMFC-A Series — Ceiling Concealed Duct — full technical specifications, transcribed from the official Daikin brochure.
SpecificationFDMFC50AV1MFDMFC60AV1MFDMFC71AV1MFDMFC85AV1MFDMFC100AV1MFDMFC125AV1MFDMFC140AV1M
Indoor unitFDMFC50AV1MFDMFC60AV1MFDMFC71AV1MFDMFC85AV1MFDMFC100AV1MFDMFC125AV1MFDMFC140AV1M
Outdoor unitRZFC50AGVMMRZFC60AGVMMRZFC71AGVMMRZFC85AVMMRZFC100AVMMRZFC125AY1MRZFC140AY1M
Cooling capacity (kW)5.42 (2.30-5.60)6.00 (2.60-6.30)7.10 (3.20-8.00)8.79 (4.20-10.00)10.55 (5.00-11.20)12.31 (5.70-14.00)14.07 (6.20-15.50)
Cooling capacity (Btu/h)18,500 (7,800-19,100)20,500 (8,900-21,500)24,200 (10,900-27,300)30,000 (14,300-34,100)36,000 (17,100-38,200)42,000 (19,500-47,800)48,000 (21,200-52,900)
CSPF (Wh/Wh)4.164.134.364.76Not stated in the official Daikin brochure.Not stated in the official Daikin brochure.Not stated in the official Daikin brochure.
Power consumption (W)1,9402,3002,1502,7703,5204,6805,390
Running current (A)8.5110.109.2012.40Not stated in the official Daikin brochure.Not stated in the official Daikin brochure.Not stated in the official Daikin brochure.
Airflow (cfm)590 / 525 / 430590 / 525 / 430950 / 810 / 700950 / 810 / 700Not stated in the official Daikin brochure.Not stated in the official Daikin brochure.Not stated in the official Daikin brochure.
Indoor sound (dB(A))40 / 37 / 3440 / 37 / 3441 / 38 / 3541 / 38 / 35Not stated in the official Daikin brochure.Not stated in the official Daikin brochure.Not stated in the official Daikin brochure.
Outdoor sound (dB(A))52525253Not stated in the official Daikin brochure.Not stated in the official Daikin brochure.Not stated in the official Daikin brochure.
Indoor dimensions H×W×D (mm)250 x 700 x 700250 x 700 x 700250 x 1,000 x 700250 x 1,000 x 700Not stated in the official Daikin brochure.Not stated in the official Daikin brochure.Not stated in the official Daikin brochure.
Outdoor dimensions H×W×D (mm)615 x 845 x 300615 x 845 x 300615 x 845 x 300695 x 930 x 350Not stated in the official Daikin brochure.Not stated in the official Daikin brochure.Not stated in the official Daikin brochure.
Indoor weight (kg)24243131Not stated in the official Daikin brochure.Not stated in the official Daikin brochure.Not stated in the official Daikin brochure.
Outdoor weight (kg)37373740Not stated in the official Daikin brochure.Not stated in the official Daikin brochure.Not stated in the official Daikin brochure.
Official Daikin catalogueDaikin product page

Figures transcribed from Daikin brochure RC-0921-H, September 2021, revision H.

The Daikin FDMC-A ceiling concealed ducted unit.

FDMC-A Series — Ceiling Concealed Duct (Non-Inverter)

SkyAir non-inverter ducted units covering seven capacity classes to class 160, plus the compact FDBC 25 and 35 classes for small rooms.

Compressor
Non-Inverter
Refrigerant
R32
Capacity
Energy rating
Models
9
Best for
Concealed installations where inverter payback does not apply
Specifications and model numbers
Class 25 to class 160
The FDBC 25 and 35 classes cover single small rooms; FDMC runs from 50 to 160 for larger areas.
Model numbers (9)
FDMC-A Series — Ceiling Concealed Duct (Non-Inverter) — model numbers with cooling capacity.
Indoor unitOutdoor unitCooling capacity
FDBC25AV1MRC25AV1MClass 25 — kW figure not stated in the official Daikin brochure.
FDBC35AV1MRC35AV1MClass 35 — kW figure not stated in the official Daikin brochure.
FDMC50AV1MRC50AV1MClass 50 — kW figure not stated in the official Daikin brochure.
FDMC60AV1MRC60AV1MClass 60 — kW figure not stated in the official Daikin brochure.
FDMC85AV1MRC85AV1MClass 85 — kW figure not stated in the official Daikin brochure.
FDMC100AV1MRC100AV1MClass 100 — kW figure not stated in the official Daikin brochure.
FDMC125AV1MRC125AY1MClass 125 — kW figure not stated in the official Daikin brochure.
FDMC140AV1MRC140AY1MClass 140 — kW figure not stated in the official Daikin brochure.
FDMC160AV1MRC160AY1MClass 160 — kW figure not stated in the official Daikin brochure.
Official Daikin catalogueDaikin product page

Figures transcribed from Daikin brochure RC-0821-G, August 2021, revision G.

Send us the room and the ceiling. We will size it and name the model.

Get a recommendation
A Daikin ceiling-suspended unit mounted below the slab in a retail store.

Ceiling Suspended

Mounted below the ceiling slab and discharging horizontally along it. Used where there is no ceiling void to conceal a unit and no suitable wall.

Specified for: Shop lots and workshops with exposed soffits; Rooms with high ceilings and limited wall space.

The Daikin FHA-B ceiling-suspended indoor unit.

FHA-B Series — Ceiling Suspended (Inverter)

SkyAir inverter ceiling-suspended units in six capacity classes, mounted below the slab and discharging horizontally along the ceiling.

Compressor
Inverter
Refrigerant
R32
Capacity
Energy rating
Models
6
Best for
Shop lots and units with exposed soffits and no ceiling void
Specifications and model numbers
No ceiling void required
The unit mounts to the slab. Where a ducted or cassette unit cannot be used because there is nothing to recess into, this is the format that fits.
Horizontal throw along the ceiling
Air is discharged along the ceiling plane rather than down at occupants, which suits rooms that are long relative to their width.
Model numbers (6)
FHA-B Series — Ceiling Suspended (Inverter) — model numbers with cooling capacity.
Indoor unitOutdoor unitCooling capacity
FHA50BVMARZF50CVMClass 50 — kW figure not stated in the official Daikin brochure.
FHA60BVMARZF60CVMClass 60 — kW figure not stated in the official Daikin brochure.
FHA71BVMARZF71CClass 71 — kW figure not stated in the official Daikin brochure.
FHA100BVMARZF100CVMClass 100 — kW figure not stated in the official Daikin brochure.
FHA125BVMARZF125CVMClass 125 — kW figure not stated in the official Daikin brochure.
FHA140BVMARZF140CVMClass 140 — kW figure not stated in the official Daikin brochure.
Official Daikin catalogueDaikin product page

Figures transcribed from Daikin brochure RZF-1217-A, December 2017, revision A.

The Daikin FHC-A ceiling-suspended indoor unit.

FHC-A Series — Ceiling Suspended (Non-Inverter)

SkyAir non-inverter ceiling-suspended units in seven capacity classes up to class 160 — the largest single-split capacity in this catalogue set.

Compressor
Non-Inverter
Refrigerant
R32
Capacity
Energy rating
Models
7
Best for
Large shop lots, workshops and warehouses with exposed soffits
Specifications and model numbers
Up to class 160
The largest single-split indoor capacity across these catalogues, for spaces a 140 class cannot cover from one unit.
Model numbers (7)
FHC-A Series — Ceiling Suspended (Non-Inverter) — model numbers with cooling capacity.
Indoor unitOutdoor unitCooling capacity
FHC50AV1MRC50AV1MClass 50 — kW figure not stated in the official Daikin brochure.
FHC60AV1MRC60AV1MClass 60 — kW figure not stated in the official Daikin brochure.
FHC85AV1MRC85AV1MClass 85 — kW figure not stated in the official Daikin brochure.
FHC100AV1MRC100AV1MClass 100 — kW figure not stated in the official Daikin brochure.
FHC125AV1MRC125AY1MClass 125 — kW figure not stated in the official Daikin brochure.
FHC140AV1MRC140AY1MClass 140 — kW figure not stated in the official Daikin brochure.
FHC160AV1MRC160AY1MClass 160 — kW figure not stated in the official Daikin brochure.
Official Daikin catalogueDaikin product page

Figures transcribed from Daikin brochure RC-0821-G, August 2021, revision G.

Send us the room and the ceiling. We will size it and name the model.

Get a recommendation

Floor Standing

Free-standing units delivering high airflow at low level. Specified for large open spaces with no usable ceiling.

4 models

The Daikin FVC-A floor-standing indoor unit.

FVC-A Series — Floor Standing

R32 non-inverter floor-standing units in four capacity classes covering 29,000 to 48,000 Btu/h.

Best for: Halls, surau, workshops and showrooms with no suitable ceiling

Capacity
29,000–48,000 Btu/h
Models
4
Specifications and model numbers
Full 4TR at the 140 class
R32 raises the 140 class from 45,000 Btu/h under R410A to 48,000 Btu/h — the brochure states this as a full 4 tons of refrigeration.
11% average EER improvement
The brochure records average EER rising from 2.89 on R410A to 3.24 on R32 across the range.
High airflow
Stated as bringing large spaces down to setpoint rapidly, which is the reason this format is specified over ceiling units in halls.
  • Spaces needing high airflow reaching across a large floor area
  • Replacements where existing pipework runs at low level
Model numbers (4)
FVC-A Series — Floor Standing — model numbers with cooling capacity.
Indoor unitOutdoor unitCooling capacity
FVC85AV1M9RC85BY1M / RC85AGY1M29,000 Btu/h
FVC100AV1MRC100BY1M / RC100AGY1M36,000 Btu/h
FVC125AV1MRC125BY1M9 / RC125AGY1M942,000 Btu/h
FVC140AV1MRC140BY1M9 / RC140AGY1M948,000 (full 4TR) Btu/h
Official Daikin catalogueDaikin product page

Figures transcribed from Daikin brochure FVC-0425-C, April 2025, revision C.

Send us the room and the ceiling. We will size it and name the model.

Get a recommendation
A bank of Daikin VRV outdoor modules installed outside a building.

Daikin flagship commercial system

VRV / VRF

One outdoor system driving many indoor units of mixed type, each independently controlled. The format specified for whole floors, whole buildings and multi-zone fit-outs.

Specified for: Office floors and multi-tenant buildings; F&B outlets with kitchen, dining and private rooms on one system; Premium residential whole-house systems.

Single circuit range
6–78HP
Indoor unit families
13
Model numbers
155
A Daikin VRV 6 X double-module outdoor unit.

Flagship

VRV 6 X Series — Outdoor

Daikin's highest-efficiency VRV outdoor range, cooling only.

Capacity
54,600–573,000 Btu/h
Models
28
Refrigerant
R410A
  • EER up to 5.37 Outdoor EER by capacity: 5.37 at 6HP, 5.35 at 8HP, 5.11 at 10HP, 4.58 at 12HP, 4.76 at 14HP, 4.65 at 16HP, 4.39 at 18HP, 4.38 at 20HP — an average improvement of about 12.9% over the previous generation.
  • Silver HeatX parallel flow condenser A flat-channel heat exchanger in place of cross-fin, using 31.3% less refrigerant. Certified to ISO 12944-6:2018 and ISO 9227:2017, having passed a 1,440-hour salt spray test at C5 level.
  • VRT Smart II control Refrigerant evaporating temperature is adjusted to the actual heat load rather than held fixed, which raises EER at part load — where a commercial system spends most of its hours.
Specifications and model numbers
Model numbers (28)
VRV 6 X Series — Outdoor — model numbers with cooling capacity.
ModelHorsepowerCooling capacity
RXUQ6BYM6HP54,600 Btu/h
RXUQ8BYM8HP76,400 Btu/h
RXUQ10BYM10HP96,000 Btu/h
RXUQ12BYM12HP114,000 Btu/h
RXUQ14BYM14HP136,000 Btu/h
RXUQ16BYM16HP154,000 Btu/h
RXUQ18BYM18HP171,000 Btu/h
RXUQ20BYM20HP191,000 Btu/h
RXUQ22BYM22HP210,000 Btu/h
RXUQ24BYM24HP229,000 Btu/h
RXUQ26BYM26HP251,000 Btu/h
RXUQ28BYM28HP268,000 Btu/h
RXUQ30BYM30HP285,000 Btu/h
RXUQ32BYM32HP305,000 Btu/h
RXUQ34BYM34HP328,000 Btu/h
RXUQ36BYM36HP345,000 Btu/h
RXUQ38BYM38HP362,000 Btu/h
RXUQ40BYM40HP382,000 Btu/h
RXUQ42BYM42HP399,000 Btu/h
RXUQ44BYM44HP420,000 Btu/h
RXUQ46BYM46HP440,000 Btu/h
RXUQ48BYM48HP457,000 Btu/h
RXUQ50BYM50HP474,000 Btu/h
RXUQ52BYM52HP495,000 Btu/h
RXUQ54BYM54HP519,000 Btu/h
RXUQ56BYM56HP536,000 Btu/h
RXUQ58BYM58HP553,000 Btu/h
RXUQ60BYM60HP573,000 Btu/h
Design and installation limits
Maximum actual piping length
165 m (190 m equivalent)
Maximum total piping length
1,000 m
Height difference, outdoor to indoor
110 m
Height difference between indoor units
30 m
First branch to farthest indoor unit
40 m standard, up to 90 m subject to conditions
Connection ratio
50% – 200%
Power supply
3-phase 4-wire, 380–415 V / 380 V, 50/60 Hz

Control: intelligent Touch Manager (DCM601) and intelligent Touch Controller for centralised control; BRC1H63W/K and BRC1E63 at room level. Building management integration over DIII-NET, with BACnet, LonWorks and Modbus interfaces.

Official Daikin catalogueDaikin product page

Figures transcribed from Daikin brochure VRV-1025-K, October 2025, revision K.

VRV 6 A Series — Outdoor

76,400–747,000 Btu/h · 36 models

The VRV 6 range built for capacity and plant-space economy, cooling only.

Model numbers and specifications
26HP from a single casing
At 26HP the new single module occupies 1.34 m² against 1.68 m² for the previous two-casing combination — 20% less installation space and 11% less weight, at 354 kg against 400 kg.
78HP on one circuit
Single modules cover 8–26HP, doubles 28–52HP and triples 54–78HP, so one refrigerant circuit can serve a whole building rather than being split into several systems.
EER up to 4.48
About 7% better than the previous generation on average across 8–20HP, from a new compressor and VRT Smart II control.
Reinforced frame
Truss-shaped support with each part screwed on two axes. Daikin's Japanese model was tested by the National Institute of Technology and Evaluation against a seismic intensity 7 earthquake and 60 m/s winds.
Model numbers (36)
VRV 6 A Series — Outdoor — model numbers with cooling capacity.
ModelHorsepowerCooling capacity
RXQ8BYM8HP76,400 Btu/h
RXQ10BYM10HP95,500 Btu/h
RXQ12BYM12HP114,000 Btu/h
RXQ14BYM14HP136,000 Btu/h
RXQ16BYM16HP154,000 Btu/h
RXQ18BYM18HP171,000 Btu/h
RXQ20BYM20HP191,000 Btu/h
RXQ22BYM22HP210,000 Btu/h
RXQ24BYM24HP229,000 Btu/h
RXQ26BYM26HP249,000 Btu/h
RXQ28BYM28HP268,000 Btu/h
RXQ30BYM30HP285,000 Btu/h
RXQ32BYM32HP305,000 Btu/h
RXQ34BYM34HP324,000 Btu/h
RXQ36BYM36HP341,000 Btu/h
RXQ38BYM38HP362,000 Btu/h
RXQ40BYM40HP382,000 Btu/h
RXQ42BYM42HP399,000 Btu/h
RXQ44BYM44HP420,000 Btu/h
RXQ46BYM46HP440,000 Btu/h
RXQ48BYM48HP457,000 Btu/h
RXQ50BYM50HP478,000 Btu/h
RXQ52BYM52HP498,000 Btu/h
RXQ54BYM54HP512,000 Btu/h
RXQ56BYM56HP532,000 Btu/h
RXQ58BYM58HP553,000 Btu/h
RXQ60BYM60HP573,000 Btu/h
RXQ62BYM62HP590,000 Btu/h
RXQ64BYM64HP611,000 Btu/h
RXQ66BYM66HP631,000 Btu/h
RXQ68BYM68HP648,000 Btu/h
RXQ70BYM70HP669,000 Btu/h
RXQ72BYM72HP689,000 Btu/h
RXQ74BYM74HP706,000 Btu/h
RXQ76BYM76HP727,000 Btu/h
RXQ78BYM78HP747,000 Btu/h

Control: Shares the VRV control platform: intelligent Touch Manager (DCM601), BRC1H63W/K and BRC1E63 room controllers, DIII-NET, and BACnet, LonWorks and Modbus building management interfaces.

Official Daikin catalogueDaikin product page

Figures transcribed from Daikin brochure VRV-1025-K, October 2025, revision K.

VRV Indoor Units

0.8–20HP · 91 models

Thirteen indoor families share one VRV circuit, which is the reason VRV is specified on fit-outs where the ceiling treatment changes room by room.

Model numbers and specifications
Cassettes — FXFQ, FXFRQ, FXFSQ, FXZQ
Round Flow with 360° discharge, a Sensing variant that reads occupancy and floor temperature, a Streamer variant that irradiates the filter, and a Compact Multi Flow that fits a 600 × 600 mm ceiling module.
Ducted — FXDQ, FXDBQ, FXSQ, FXMQ
Slim duct for shallow voids, a bedroom duct for hotels and condominiums, then middle, middle-high and high static pressure units up to class 250 where duct runs are long.
Exposed — FXAQ, FXHQ, FXVQ
Wall mounted to class 100, ceiling suspended to class 140, and floor standing duct to class 500 for large volumes with no usable ceiling.
Fresh air — FXMQ-MF, FXMQ-BF, VAM
Outdoor-Air Processing units treat ventilation air on the same circuit; the VAM-HVE heat reclaim ventilator covers 150–2,000 m³/h. Air handling units are available from 6 to 120HP.
Model numbers (91)
VRV Indoor Units — model numbers with cooling capacity.
Indoor unitHorsepowerCooling capacity
FXFQ25AVM1HPCapacity index 25
FXFQ32AVM1.25HPCapacity index 32
FXFQ40AVM1.6HPCapacity index 40
FXFQ50AVM2HPCapacity index 50
FXFQ63AVM2.5HPCapacity index 63
FXFQ80AVM3.2HPCapacity index 80
FXFQ100AVM4HPCapacity index 100
FXFQ125AVM5HPCapacity index 125
FXFQ140AVM6HPCapacity index 140
FXFRQ25AVM1HPCapacity index 25
FXFRQ32AVM1.25HPCapacity index 32
FXFRQ40AVM1.6HPCapacity index 40
FXFRQ50AVM2HPCapacity index 50
FXFRQ63AVM2.5HPCapacity index 63
FXFRQ80AVM3.2HPCapacity index 80
FXFRQ100AVM4HPCapacity index 100
FXFRQ125AVM5HPCapacity index 125
FXFRQ140AVM6HPCapacity index 140
FXFSQ25AVM1HPCapacity index 25
FXFSQ32AVM1.25HPCapacity index 32
FXFSQ40AVM1.6HPCapacity index 40
FXFSQ50AVM2HPCapacity index 50
FXFSQ63AVM2.5HPCapacity index 63
FXFSQ80AVM3.2HPCapacity index 80
FXFSQ100AVM4HPCapacity index 100
FXFSQ125AVM5HPCapacity index 125
FXFSQ140AVM6HPCapacity index 140
FXZQ20BVM0.8HPCapacity index 20
FXZQ25BVM1HPCapacity index 25
FXZQ32BVM1.25HPCapacity index 32
FXZQ40BVM1.6HPCapacity index 40
FXZQ50BVM2HPCapacity index 50
FXDBQ40AVM1.6HPCapacity index 40
FXDBQ50AVM2HPCapacity index 50
FXDBQ63AVM2.5HPCapacity index 63
FXDBQ80AVM3.2HPCapacity index 80
FXDQ20PDVE0.8HPCapacity index 20
FXDQ25PDVE1HPCapacity index 25
FXDQ32PDVE1.25HPCapacity index 32
FXDQ40NDVE1.6HPCapacity index 40
FXDQ50NDVE2HPCapacity index 50
FXDQ63NDVE2.5HPCapacity index 63
FXSQ20PAVE0.8HPCapacity index 20
FXSQ25PAVE1HPCapacity index 25
FXSQ32PAVE1.25HPCapacity index 32
FXSQ40PAVE1.6HPCapacity index 40
FXSQ50PAVE2HPCapacity index 50
FXSQ63PAVE2.5HPCapacity index 63
FXSQ80PAVE3.2HPCapacity index 80
FXSQ100PAVE4HPCapacity index 100
FXSQ125PAVE5HPCapacity index 125
FXSQ140PAVE6HPCapacity index 140
FXMQ20PAVE0.8HPCapacity index 20
FXMQ25PAVE1HPCapacity index 25
FXMQ32PAVE1.25HPCapacity index 32
FXMQ40PAVE1.6HPCapacity index 40
FXMQ50PAVE2HPCapacity index 50
FXMQ63PAVE2.5HPCapacity index 63
FXMQ80PAVE3.2HPCapacity index 80
FXMQ100PAVE4HPCapacity index 100
FXMQ125PAVE5HPCapacity index 125
FXMQ140PAVE6HPCapacity index 140
FXMQ200PVM8HPCapacity index 200
FXMQ250PVM10HPCapacity index 250
FXHQ32MAVE1.25HPCapacity index 32
FXHQ63MAVE2.5HPCapacity index 63
FXHQ100MAVE4HPCapacity index 100
FXHQ125BVM5HPCapacity index 125
FXHQ140BVM6HPCapacity index 140
FXAQ20BVM0.8HPCapacity index 20
FXAQ25BVM1HPCapacity index 25
FXAQ32BVM1.25HPCapacity index 32
FXAQ40BVM1.6HPCapacity index 40
FXAQ50BVM2HPCapacity index 50
FXAQ63BVM2.5HPCapacity index 63
FXAQ71BVM3HPCapacity index 71
FXAQ80BVM3.2HPCapacity index 80
FXAQ100BVM4HPCapacity index 100
FXVQ125NY15HPCapacity index 125
FXVQ200NY18HPCapacity index 200
FXVQ250NY110HPCapacity index 250
FXVQ400NY116HPCapacity index 400
FXVQ500NY120HPCapacity index 500
FXVQ500NY1620HPCapacity index 500
FXMQ125MFV15HPCapacity index 125
FXMQ200MFV18HPCapacity index 200
FXMQ250MFV110HPCapacity index 250
FXMQ80BFVM3.2HPCapacity index 80
FXMQ140BFVM6HPCapacity index 140
FXMQ200BFVM8HPCapacity index 200
FXMQ250BFVM10HPCapacity index 250

Control: BRC1H63W/K and BRC1E63 wired controllers at room level. Streamer operation on FXFRQ is available only with BRC1H63W(K), runs only while the fan and cooling are stopped, and is capped at 180 minutes per day.

Official Daikin catalogueDaikin product page

Figures transcribed from Daikin brochure VRV-1025-K, October 2025, revision K.

VRV is designed, not picked from a list. Send us the floor plan and we will size the circuit, the branch and the plant space.

Send your floor plan

Complete model index

Every model number on this page, mapped to its series, capacity, paired unit and source brochure.

Open the full model index(396 models — 232 indoor, 164 outdoor)
Complete index of Daikin model numbers referenced on this page, with the series, category and source brochure for each.
ModelTypeSeriesCooling capacityPaired withSource
BCR50FMF panelindoorFCFC A-Series — Inverter Ceiling Cassette18,500 (7,800-19,100) Btu/hRZFC50AGVMMRC-0921-H
BCR50FMW panelindoorFCFC A-Series — Inverter Ceiling Cassette18,500 (7,800-19,100) Btu/hRZFC50AGVMMRC-0921-H
CTKC25RVMindoorMKC Series — Multi-Split2.5 kW classMKC50RVM / MKC70SVMMKC-0520-C
CTKC35RVMindoorMKC Series — Multi-Split3.5 kW classMKC50RVM / MKC70SVMMKC-0520-C
CTKC50SVMindoorMKC Series — Multi-Split5.0 kW classMKC70SVMMKC-0520-C
FCC100AV1M8indoorFCC-A Series — Ceiling CassetteNot stated in the official Daikin brochure.RC100BV1MRC-0921-H
FCC125AV1M8indoorFCC-A Series — Ceiling CassetteNot stated in the official Daikin brochure.RC125BY1MRC-0921-H
FCC140AV1M8indoorFCC-A Series — Ceiling CassetteNot stated in the official Daikin brochure.RC140BY1MRC-0921-H
FCC50AV1M8indoorFCC-A Series — Ceiling CassetteNot stated in the official Daikin brochure.RC50BV1MRC-0921-H
FCC60AV1M8indoorFCC-A Series — Ceiling CassetteNot stated in the official Daikin brochure.RC60BV1MRC-0921-H
FCC85AV1M8indoorFCC-A Series — Ceiling CassetteNot stated in the official Daikin brochure.RC85BV1MRC-0921-H
FCFC100AV1MFindoorFCFC A-Series — Inverter Ceiling Cassette36,000 (17,100-38,200) Btu/hRZFC100AVMMRC-0921-H
FCFC125AV1MFindoorFCFC A-Series — Inverter Ceiling Cassette42,000 (19,500-47,800) Btu/hRZFC125AY1MRC-0921-H
FCFC140AV1MFindoorFCFC A-Series — Inverter Ceiling Cassette48,000 (21,200-52,900) Btu/hRZFC140AY1MRC-0921-H
FCFC50AV1MFindoorFCFC A-Series — Inverter Ceiling Cassette18,500 (7,800-19,100) Btu/hRZFC50AGVMMRC-0921-H
FCFC60AV1MFindoorFCFC A-Series — Inverter Ceiling Cassette20,500 (8,900-21,500) Btu/hRZFC60AGVMMRC-0921-H
FCFC71AV1MFindoorFCFC A-Series — Inverter Ceiling Cassette24,200 (10,900-27,300) Btu/hRZFC71AGVMMRC-0921-H
FCFC85AV1MFindoorFCFC A-Series — Inverter Ceiling Cassette30,000 (14,300-34,100) Btu/hRZFC85AVMMRC-0921-H
FCFG100AV1MFindoorFCFG Series — REVO Max Surround Cassette36,000 (17,100-38,200) Btu/hRZFG100AVMMFCFG-0825-E
FCFG125AV1MFindoorFCFG Series — REVO Max Surround Cassette42,000 (19,500-47,800) Btu/hRZFG125AY1MFCFG-0825-E
FCFG140AV1MFindoorFCFG Series — REVO Max Surround Cassette48,000 (21,200-52,900) Btu/hRZFG140AY1MFCFG-0825-E
FCFG50AV1MF9indoorFCFG Series — REVO Max Surround Cassette18,500 (7,800-19,100) Btu/hRZFG50AGVMMFCFG-0825-E
FCFG60AV1MF9indoorFCFG Series — REVO Max Surround Cassette20,500 (8,900-21,500) Btu/hRZFG60AGVMMFCFG-0825-E
FCFG71AV1MF9indoorFCFG Series — REVO Max Surround Cassette24,200 (10,900-27,300) Btu/hRZFG71AGVMMFCFG-0825-E
FCFG85AV1MF9indoorFCFG Series — REVO Max Surround Cassette30,000 (14,300-34,100) Btu/hRZFG85AVMMFCFG-0825-E
FCFV100AV1MFindoorFCFV Series — Ceiling Cassette (Non-Inverter)Class 100 — kW figure not stated in the official Daikin brochure.RGFV100AV1MFCFV-1221-A
FCFV125AV1MFindoorFCFV Series — Ceiling Cassette (Non-Inverter)Class 125 — kW figure not stated in the official Daikin brochure.RGFV125AY1MFCFV-1221-A
FCFV18AV1SindoorFCFV Series — Ceiling Cassette (Non-Inverter)Class 18 — kW figure not stated in the official Daikin brochure.RGFV18AV1SFCFV-1221-A
FCFV24AV1SindoorFCFV Series — Ceiling Cassette (Non-Inverter)Class 24 — kW figure not stated in the official Daikin brochure.RGFV24AV1SFCFV-1221-A
FCFV30AV1SindoorFCFV Series — Ceiling Cassette (Non-Inverter)Class 30 — kW figure not stated in the official Daikin brochure.RGFV30AV1SFCFV-1221-A
FCFV36AV1SindoorFCFV Series — Ceiling Cassette (Non-Inverter)Class 36 — kW figure not stated in the official Daikin brochure.RGFV36AV1SFCFV-1221-A
FCFV42AV1SindoorFCFV Series — Ceiling Cassette (Non-Inverter)Class 42 — kW figure not stated in the official Daikin brochure.RGFV42AY1SFCFV-1221-A
FCFV46AV1SindoorFCFV Series — Ceiling Cassette (Non-Inverter)Class 46 — kW figure not stated in the official Daikin brochure.RGFV46AY1SFCFV-1221-A
FCFV50AV1MFindoorFCFV Series — Ceiling Cassette (Non-Inverter)Class 50 — kW figure not stated in the official Daikin brochure.RGFV50AV1MFCFV-1221-A
FCFV60AV1MFindoorFCFV Series — Ceiling Cassette (Non-Inverter)Class 60 — kW figure not stated in the official Daikin brochure.RGFV60AV1MFCFV-1221-A
FCFV85AV1MFindoorFCFV Series — Ceiling Cassette (Non-Inverter)Class 85 — kW figure not stated in the official Daikin brochure.RGFV85AV1MFCFV-1221-A
FDBC25AV1MindoorFDMC-A Series — Ceiling Concealed Duct (Non-Inverter)Class 25 — kW figure not stated in the official Daikin brochure.RC25AV1MRC-0821-G
FDBC35AV1MindoorFDMC-A Series — Ceiling Concealed Duct (Non-Inverter)Class 35 — kW figure not stated in the official Daikin brochure.RC35AV1MRC-0821-G
FDMC100AV1MindoorFDMC-A Series — Ceiling Concealed Duct (Non-Inverter)Class 100 — kW figure not stated in the official Daikin brochure.RC100AV1MRC-0821-G
FDMC125AV1MindoorFDMC-A Series — Ceiling Concealed Duct (Non-Inverter)Class 125 — kW figure not stated in the official Daikin brochure.RC125AY1MRC-0821-G
FDMC140AV1MindoorFDMC-A Series — Ceiling Concealed Duct (Non-Inverter)Class 140 — kW figure not stated in the official Daikin brochure.RC140AY1MRC-0821-G
FDMC160AV1MindoorFDMC-A Series — Ceiling Concealed Duct (Non-Inverter)Class 160 — kW figure not stated in the official Daikin brochure.RC160AY1MRC-0821-G
FDMC50AV1MindoorFDMC-A Series — Ceiling Concealed Duct (Non-Inverter)Class 50 — kW figure not stated in the official Daikin brochure.RC50AV1MRC-0821-G
FDMC60AV1MindoorFDMC-A Series — Ceiling Concealed Duct (Non-Inverter)Class 60 — kW figure not stated in the official Daikin brochure.RC60AV1MRC-0821-G
FDMC85AV1MindoorFDMC-A Series — Ceiling Concealed Duct (Non-Inverter)Class 85 — kW figure not stated in the official Daikin brochure.RC85AV1MRC-0821-G
FDMFC100AV1MindoorFDMFC-A Series — Ceiling Concealed Duct36,000 (17,100-38,200) Btu/hRZFC100AVMMRC-0921-H
FDMFC125AV1MindoorFDMFC-A Series — Ceiling Concealed Duct42,000 (19,500-47,800) Btu/hRZFC125AY1MRC-0921-H
FDMFC140AV1MindoorFDMFC-A Series — Ceiling Concealed Duct48,000 (21,200-52,900) Btu/hRZFC140AY1MRC-0921-H
FDMFC50AV1MindoorFDMFC-A Series — Ceiling Concealed Duct18,500 (7,800-19,100) Btu/hRZFC50AGVMMRC-0921-H
FDMFC60AV1MindoorFDMFC-A Series — Ceiling Concealed Duct20,500 (8,900-21,500) Btu/hRZFC60AGVMMRC-0921-H
FDMFC71AV1MindoorFDMFC-A Series — Ceiling Concealed Duct24,200 (10,900-27,300) Btu/hRZFC71AGVMMRC-0921-H
FDMFC85AV1MindoorFDMFC-A Series — Ceiling Concealed Duct30,000 (14,300-34,100) Btu/hRZFC85AVMMRC-0921-H
FHA100BVMAindoorFHA-B Series — Ceiling Suspended (Inverter)Class 100 — kW figure not stated in the official Daikin brochure.RZF100CVMRZF-1217-A
FHA125BVMAindoorFHA-B Series — Ceiling Suspended (Inverter)Class 125 — kW figure not stated in the official Daikin brochure.RZF125CVMRZF-1217-A
FHA140BVMAindoorFHA-B Series — Ceiling Suspended (Inverter)Class 140 — kW figure not stated in the official Daikin brochure.RZF140CVMRZF-1217-A
FHA50BVMAindoorFHA-B Series — Ceiling Suspended (Inverter)Class 50 — kW figure not stated in the official Daikin brochure.RZF50CVMRZF-1217-A
FHA60BVMAindoorFHA-B Series — Ceiling Suspended (Inverter)Class 60 — kW figure not stated in the official Daikin brochure.RZF60CVMRZF-1217-A
FHA71BVMAindoorFHA-B Series — Ceiling Suspended (Inverter)Class 71 — kW figure not stated in the official Daikin brochure.RZF71CRZF-1217-A
FHC100AV1MindoorFHC-A Series — Ceiling Suspended (Non-Inverter)Class 100 — kW figure not stated in the official Daikin brochure.RC100AV1MRC-0821-G
FHC125AV1MindoorFHC-A Series — Ceiling Suspended (Non-Inverter)Class 125 — kW figure not stated in the official Daikin brochure.RC125AY1MRC-0821-G
FHC140AV1MindoorFHC-A Series — Ceiling Suspended (Non-Inverter)Class 140 — kW figure not stated in the official Daikin brochure.RC140AY1MRC-0821-G
FHC160AV1MindoorFHC-A Series — Ceiling Suspended (Non-Inverter)Class 160 — kW figure not stated in the official Daikin brochure.RC160AY1MRC-0821-G
FHC50AV1MindoorFHC-A Series — Ceiling Suspended (Non-Inverter)Class 50 — kW figure not stated in the official Daikin brochure.RC50AV1MRC-0821-G
FHC60AV1MindoorFHC-A Series — Ceiling Suspended (Non-Inverter)Class 60 — kW figure not stated in the official Daikin brochure.RC60AV1MRC-0821-G
FHC85AV1MindoorFHC-A Series — Ceiling Suspended (Non-Inverter)Class 85 — kW figure not stated in the official Daikin brochure.RC85AV1MRC-0821-G
FTKB25AV1MindoorFTKB Series9,000 (3,500 - 9,200) Btu/hRKB25AV1MFTKB-1225-A
FTKB35AV1MindoorFTKB Series12,300 (4,100 - 12,800) Btu/hRKB35AV1MFTKB-1225-A
FTKB50AV1MindoorFTKB Series18,000 (5,600 - 18,500) Btu/hRKB50AV1MFTKB-1225-A
FTKB71AV1MindoorFTKB Series24,000 (6,600 - 24,500) Btu/hRKB71AV1MFTKB-1225-A
FTKB75AV1MindoorFTKB Series25,600 (7,900 - 29,000) Btu/hRKB75AV1MFTKB-1225-A
FTKE25AV1MindoorFTKE Series9,000 (3,500 - 9,200) Btu/hRKE25AV1MFTKE-0724-A
FTKE25AV1MFindoorFTKE Series9,000 (3,500 - 9,200) Btu/hRKE25AV1MFTKE-0724-A
FTKE25AV1MWindoorFTKE Series9,000 (3,500 - 9,200) Btu/hRKE25AV1MFTKE-0724-A
FTKE35AV1MindoorFTKE Series12,300 (4,100 - 12,800) Btu/hRKE35AV1MFTKE-0724-A
FTKE35AV1MFindoorFTKE Series12,300 (4,100 - 12,800) Btu/hRKE35AV1MFTKE-0724-A
FTKE35AV1MWindoorFTKE Series12,300 (4,100 - 12,800) Btu/hRKE35AV1MFTKE-0724-A
FTKE50AV1MindoorFTKE Series18,000 (5,200 - 18,500) Btu/hRKE50AV1MFTKE-0724-A
FTKE50AV1MFindoorFTKE Series18,000 (5,200 - 18,500) Btu/hRKE50AV1MFTKE-0724-A
FTKE50AV1MWindoorFTKE Series18,000 (5,200 - 18,500) Btu/hRKE50AV1MFTKE-0724-A
FTKE71AV1MindoorFTKE Series24,000 (6,600 - 24,500) Btu/hRKE71AV1MFTKE-0724-A
FTKE71AV1MFindoorFTKE Series24,000 (6,600 - 24,500) Btu/hRKE71AV1MFTKE-0724-A
FTKE71AV1MWindoorFTKE Series24,000 (6,600 - 24,500) Btu/hRKE71AV1MFTKE-0724-A
FTKF25CV1MindoorFTKF Series9,000 (3,400 - 9,200) Btu/hRKF25CV1M9FTKF-0824-J
FTKF25CV1MFindoorFTKF Series9,000 (3,400 - 9,200) Btu/hRKF25CV1M9FTKF-0824-J
FTKF25CV1MWindoorFTKF Series9,000 (3,400 - 9,200) Btu/hRKF25CV1M9FTKF-0824-J
FTKF35CV1MindoorFTKF Series12,300 (4,100 - 13,000) Btu/hRKF35CV1MFTKF-0824-J
FTKF35CV1MFindoorFTKF Series12,300 (4,100 - 13,000) Btu/hRKF35CV1MFTKF-0824-J
FTKF35CV1MWindoorFTKF Series12,300 (4,100 - 13,000) Btu/hRKF35CV1MFTKF-0824-J
FTKF50CV1MindoorFTKF Series18,000 (5,200 - 18,500) Btu/hRKF50CV1MFTKF-0824-J
FTKF50CV1MFindoorFTKF Series18,000 (5,200 - 18,500) Btu/hRKF50CV1MFTKF-0824-J
FTKF50CV1MWindoorFTKF Series18,000 (5,200 - 18,500) Btu/hRKF50CV1MFTKF-0824-J
FTKF71CV1MindoorFTKF Series24,000 (6,600 - 24,500) Btu/hRKF71CV1MFTKF-0824-J
FTKF71CV1MFindoorFTKF Series24,000 (6,600 - 24,500) Btu/hRKF71CV1MFTKF-0824-J
FTKF71CV1MWindoorFTKF Series24,000 (6,600 - 24,500) Btu/hRKF71CV1MFTKF-0824-J
FTKF75CV1MindoorFTKF Series25,600 (7,900 - 29,000) Btu/hRKF75CV1MFTKF-0824-J
FTKF75CV1MFindoorFTKF Series25,600 (7,900 - 29,000) Btu/hRKF75CV1MFTKF-0824-J
FTKH28BV1MFindoorFTKH Series — Smarto9,700 (3,700 - 11,600) Btu/hRKU28BV1MFTKH-0426-M
FTKH35BV1MFindoorFTKH Series — Smarto12,100 (4,000 - 13,000) Btu/hRKU35BV1MFTKH-0426-M
FTKH50BV1MFindoorFTKH Series — Smarto19,000 (6,000 - 21,200) Btu/hRKU50BV1MFTKH-0426-M
FTKM25PVMindoorMKM Series — Multi-Split (DC Inverter)Class 25 — kW figure not stated in the official Daikin brochure.MKM65PVM / MKM80PVM / MKM95PVM / MKM105PVMMKM-0520-C
FTKM25TVMMindoorFTKM Series8,500 (4,100 - 12,300) Btu/hRKM25TVMMFTKM-0323-D-L
FTKM35PVMindoorMKM Series — Multi-Split (DC Inverter)Class 35 — kW figure not stated in the official Daikin brochure.MKM65PVM / MKM80PVM / MKM95PVM / MKM105PVMMKM-0520-C
FTKM35TVMMindoorFTKM Series11,900 (4,100 - 14,000) Btu/hRKM35TVMMFTKM-0323-D-L
FTKM42PVMindoorMKM Series — Multi-Split (DC Inverter)Class 42 — kW figure not stated in the official Daikin brochure.MKM65PVM / MKM80PVM / MKM95PVM / MKM105PVMMKM-0520-C
FTKM50PVMindoorMKM Series — Multi-Split (DC Inverter)Class 50 — kW figure not stated in the official Daikin brochure.MKM65PVM / MKM80PVM / MKM95PVM / MKM105PVMMKM-0520-C
FTKM50TVMMindoorFTKM Series17,700 (4,100 - 21,200) Btu/hRKM50TVMMFTKM-0323-D-L
FTKM60PVMindoorMKM Series — Multi-Split (DC Inverter)Class 60 — kW figure not stated in the official Daikin brochure.MKM80PVM / MKM95PVM / MKM105PVMMKM-0520-C
FTKM60TVMMindoorFTKM Series20,500 (4,100 - 24,200) Btu/hRKM60TVMMFTKM-0323-D-L
FTKM71PVMindoorMKM Series — Multi-Split (DC Inverter)Class 71 — kW figure not stated in the official Daikin brochure.MKM95PVM / MKM105PVMMKM-0520-C
FTKM71TVMMindoorFTKM Series24,200 (4,100 - 28,000) Btu/hRKM71TVMMFTKM-0323-D-L
FTKP28AV1MindoorFTKP Series9,500 (3,400 - 11,000) Btu/hRKP28AV1M9FTKP-0824-F
FTKP28AV1MFindoorFTKP Series9,500 (3,400 - 11,000) Btu/hRKP28AV1M9FTKP-0824-F
FTKP28AV1MWindoorFTKP Series9,500 (3,400 - 11,000) Btu/hRKP28AV1M9FTKP-0824-F
FTKP35AV1MindoorFTKP Series12,300 (4,100 - 13,000) Btu/hRKP35AV1MFTKP-0824-F
FTKP35AV1MFindoorFTKP Series12,300 (4,100 - 13,000) Btu/hRKP35AV1MFTKP-0824-F
FTKP35AV1MWindoorFTKP Series12,300 (4,100 - 13,000) Btu/hRKP35AV1MFTKP-0824-F
FTKP50AV1MindoorFTKP Series19,000 (6,000 - 21,200) Btu/hRKP50AV1MFTKP-0824-F
FTKP50AV1MFindoorFTKP Series19,000 (6,000 - 21,200) Btu/hRKP50AV1MFTKP-0824-F
FTKP50AV1MWindoorFTKP Series19,000 (6,000 - 21,200) Btu/hRKP50AV1MFTKP-0824-F
FTKP71AV1MindoorFTKP Series24,000 (6,600 - 24,500) Btu/hRKP71AV1MFTKP-0824-F
FTKP71AV1MFindoorFTKP Series24,000 (6,600 - 24,500) Btu/hRKP71AV1MFTKP-0824-F
FTKP71AV1MWindoorFTKP Series24,000 (6,600 - 24,500) Btu/hRKP71AV1MFTKP-0824-F
FTV28PBV1MindoorFTV-P Series9,500 Btu/hRV28PBV1M9FTV-0724-T
FTV28PBV1MF9indoorFTV-P Series9,500 Btu/hRV28PBV1M9FTV-0724-T
FTV28PBV1MW9indoorFTV-P Series9,500 Btu/hRV28PBV1M9FTV-0724-T
FTV35PBV1MindoorFTV-P Series12,000 Btu/hRV35PBV1M9FTV-0724-T
FTV35PBV1MF9indoorFTV-P Series12,000 Btu/hRV35PBV1M9FTV-0724-T
FTV35PBV1MW9indoorFTV-P Series12,000 Btu/hRV35PBV1M9FTV-0724-T
FTV50PBV1MindoorFTV-P Series18,000 Btu/hRV50PBV1MFTV-0724-T
FTV50PBV1MFindoorFTV-P Series18,000 Btu/hRV50PBV1MFTV-0724-T
FTV50PBV1MWindoorFTV-P Series18,000 Btu/hRV50PBV1MFTV-0724-T
FTV60PBV1MindoorFTV-P Series22,500 Btu/hRV60PBV1MFTV-0724-T
FTV60PBV1MFindoorFTV-P Series22,500 Btu/hRV60PBV1MFTV-0724-T
FTV60PBV1MWindoorFTV-P Series22,500 Btu/hRV60PBV1MFTV-0724-T
FTV85PBV1MindoorFTV-P Series30,000 Btu/hRC85BV1MFTV-0724-T
FTV85PBV1MFindoorFTV-P Series30,000 Btu/hRC85BV1MFTV-0724-T
FTV85PBV1MWindoorFTV-P Series30,000 Btu/hRC85BV1MFTV-0724-T
FVC100AV1MindoorFVC-A Series — Floor Standing36,000 Btu/hRC100BY1M / RC100AGY1MFVC-0425-C
FVC125AV1MindoorFVC-A Series — Floor Standing42,000 Btu/hRC125BY1M9 / RC125AGY1M9FVC-0425-C
FVC140AV1MindoorFVC-A Series — Floor Standing48,000 (full 4TR) Btu/hRC140BY1M9 / RC140AGY1M9FVC-0425-C
FVC85AV1M9indoorFVC-A Series — Floor Standing29,000 Btu/hRC85BY1M / RC85AGY1MFVC-0425-C
FXAQ100BVMindoorVRV Indoor UnitsCapacity index 100VRV-1025-K
FXAQ20BVMindoorVRV Indoor UnitsCapacity index 20VRV-1025-K
FXAQ25BVMindoorVRV Indoor UnitsCapacity index 25VRV-1025-K
FXAQ32BVMindoorVRV Indoor UnitsCapacity index 32VRV-1025-K
FXAQ40BVMindoorVRV Indoor UnitsCapacity index 40VRV-1025-K
FXAQ50BVMindoorVRV Indoor UnitsCapacity index 50VRV-1025-K
FXAQ63BVMindoorVRV Indoor UnitsCapacity index 63VRV-1025-K
FXAQ71BVMindoorVRV Indoor UnitsCapacity index 71VRV-1025-K
FXAQ80BVMindoorVRV Indoor UnitsCapacity index 80VRV-1025-K
FXDBQ40AVMindoorVRV Indoor UnitsCapacity index 40VRV-1025-K
FXDBQ50AVMindoorVRV Indoor UnitsCapacity index 50VRV-1025-K
FXDBQ63AVMindoorVRV Indoor UnitsCapacity index 63VRV-1025-K
FXDBQ80AVMindoorVRV Indoor UnitsCapacity index 80VRV-1025-K
FXDQ20PDVEindoorVRV Indoor UnitsCapacity index 20VRV-1025-K
FXDQ25PDVEindoorVRV Indoor UnitsCapacity index 25VRV-1025-K
FXDQ32PDVEindoorVRV Indoor UnitsCapacity index 32VRV-1025-K
FXDQ40NDVEindoorVRV Indoor UnitsCapacity index 40VRV-1025-K
FXDQ50NDVEindoorVRV Indoor UnitsCapacity index 50VRV-1025-K
FXDQ63NDVEindoorVRV Indoor UnitsCapacity index 63VRV-1025-K
FXFQ100AVMindoorVRV Indoor UnitsCapacity index 100VRV-1025-K
FXFQ125AVMindoorVRV Indoor UnitsCapacity index 125VRV-1025-K
FXFQ140AVMindoorVRV Indoor UnitsCapacity index 140VRV-1025-K
FXFQ25AVMindoorVRV Indoor UnitsCapacity index 25VRV-1025-K
FXFQ32AVMindoorVRV Indoor UnitsCapacity index 32VRV-1025-K
FXFQ40AVMindoorVRV Indoor UnitsCapacity index 40VRV-1025-K
FXFQ50AVMindoorVRV Indoor UnitsCapacity index 50VRV-1025-K
FXFQ63AVMindoorVRV Indoor UnitsCapacity index 63VRV-1025-K
FXFQ80AVMindoorVRV Indoor UnitsCapacity index 80VRV-1025-K
FXFRQ100AVMindoorVRV Indoor UnitsCapacity index 100VRV-1025-K
FXFRQ125AVMindoorVRV Indoor UnitsCapacity index 125VRV-1025-K
FXFRQ140AVMindoorVRV Indoor UnitsCapacity index 140VRV-1025-K
FXFRQ25AVMindoorVRV Indoor UnitsCapacity index 25VRV-1025-K
FXFRQ32AVMindoorVRV Indoor UnitsCapacity index 32VRV-1025-K
FXFRQ40AVMindoorVRV Indoor UnitsCapacity index 40VRV-1025-K
FXFRQ50AVMindoorVRV Indoor UnitsCapacity index 50VRV-1025-K
FXFRQ63AVMindoorVRV Indoor UnitsCapacity index 63VRV-1025-K
FXFRQ80AVMindoorVRV Indoor UnitsCapacity index 80VRV-1025-K
FXFSQ100AVMindoorVRV Indoor UnitsCapacity index 100VRV-1025-K
FXFSQ125AVMindoorVRV Indoor UnitsCapacity index 125VRV-1025-K
FXFSQ140AVMindoorVRV Indoor UnitsCapacity index 140VRV-1025-K
FXFSQ25AVMindoorVRV Indoor UnitsCapacity index 25VRV-1025-K
FXFSQ32AVMindoorVRV Indoor UnitsCapacity index 32VRV-1025-K
FXFSQ40AVMindoorVRV Indoor UnitsCapacity index 40VRV-1025-K
FXFSQ50AVMindoorVRV Indoor UnitsCapacity index 50VRV-1025-K
FXFSQ63AVMindoorVRV Indoor UnitsCapacity index 63VRV-1025-K
FXFSQ80AVMindoorVRV Indoor UnitsCapacity index 80VRV-1025-K
FXHQ100MAVEindoorVRV Indoor UnitsCapacity index 100VRV-1025-K
FXHQ125BVMindoorVRV Indoor UnitsCapacity index 125VRV-1025-K
FXHQ140BVMindoorVRV Indoor UnitsCapacity index 140VRV-1025-K
FXHQ32MAVEindoorVRV Indoor UnitsCapacity index 32VRV-1025-K
FXHQ63MAVEindoorVRV Indoor UnitsCapacity index 63VRV-1025-K
FXMQ100PAVEindoorVRV Indoor UnitsCapacity index 100VRV-1025-K
FXMQ125MFV1indoorVRV Indoor UnitsCapacity index 125VRV-1025-K
FXMQ125PAVEindoorVRV Indoor UnitsCapacity index 125VRV-1025-K
FXMQ140BFVMindoorVRV Indoor UnitsCapacity index 140VRV-1025-K
FXMQ140PAVEindoorVRV Indoor UnitsCapacity index 140VRV-1025-K
FXMQ200BFVMindoorVRV Indoor UnitsCapacity index 200VRV-1025-K
FXMQ200MFV1indoorVRV Indoor UnitsCapacity index 200VRV-1025-K
FXMQ200PVMindoorVRV Indoor UnitsCapacity index 200VRV-1025-K
FXMQ20PAVEindoorVRV Indoor UnitsCapacity index 20VRV-1025-K
FXMQ250BFVMindoorVRV Indoor UnitsCapacity index 250VRV-1025-K
FXMQ250MFV1indoorVRV Indoor UnitsCapacity index 250VRV-1025-K
FXMQ250PVMindoorVRV Indoor UnitsCapacity index 250VRV-1025-K
FXMQ25PAVEindoorVRV Indoor UnitsCapacity index 25VRV-1025-K
FXMQ32PAVEindoorVRV Indoor UnitsCapacity index 32VRV-1025-K
FXMQ40PAVEindoorVRV Indoor UnitsCapacity index 40VRV-1025-K
FXMQ50PAVEindoorVRV Indoor UnitsCapacity index 50VRV-1025-K
FXMQ63PAVEindoorVRV Indoor UnitsCapacity index 63VRV-1025-K
FXMQ80BFVMindoorVRV Indoor UnitsCapacity index 80VRV-1025-K
FXMQ80PAVEindoorVRV Indoor UnitsCapacity index 80VRV-1025-K
FXSQ100PAVEindoorVRV Indoor UnitsCapacity index 100VRV-1025-K
FXSQ125PAVEindoorVRV Indoor UnitsCapacity index 125VRV-1025-K
FXSQ140PAVEindoorVRV Indoor UnitsCapacity index 140VRV-1025-K
FXSQ20PAVEindoorVRV Indoor UnitsCapacity index 20VRV-1025-K
FXSQ25PAVEindoorVRV Indoor UnitsCapacity index 25VRV-1025-K
FXSQ32PAVEindoorVRV Indoor UnitsCapacity index 32VRV-1025-K
FXSQ40PAVEindoorVRV Indoor UnitsCapacity index 40VRV-1025-K
FXSQ50PAVEindoorVRV Indoor UnitsCapacity index 50VRV-1025-K
FXSQ63PAVEindoorVRV Indoor UnitsCapacity index 63VRV-1025-K
FXSQ80PAVEindoorVRV Indoor UnitsCapacity index 80VRV-1025-K
FXVQ125NY1indoorVRV Indoor UnitsCapacity index 125VRV-1025-K
FXVQ200NY1indoorVRV Indoor UnitsCapacity index 200VRV-1025-K
FXVQ250NY1indoorVRV Indoor UnitsCapacity index 250VRV-1025-K
FXVQ400NY1indoorVRV Indoor UnitsCapacity index 400VRV-1025-K
FXVQ500NY1indoorVRV Indoor UnitsCapacity index 500VRV-1025-K
FXVQ500NY16indoorVRV Indoor UnitsCapacity index 500VRV-1025-K
FXZQ20BVMindoorVRV Indoor UnitsCapacity index 20VRV-1025-K
FXZQ25BVMindoorVRV Indoor UnitsCapacity index 25VRV-1025-K
FXZQ32BVMindoorVRV Indoor UnitsCapacity index 32VRV-1025-K
FXZQ40BVMindoorVRV Indoor UnitsCapacity index 40VRV-1025-K
FXZQ50BVMindoorVRV Indoor UnitsCapacity index 50VRV-1025-K
MKC50RVM / MKC70SVMoutdoorMKC Series — Multi-Split2.5 kW classCTKC25RVMMKC-0520-C
MKC70SVMoutdoorMKC Series — Multi-Split5.0 kW classCTKC50SVMMKC-0520-C
MKM65PVM / MKM80PVM / MKM95PVM / MKM105PVMoutdoorMKM Series — Multi-Split (DC Inverter)Class 25 — kW figure not stated in the official Daikin brochure.FTKM25PVMMKM-0520-C
MKM80PVM / MKM95PVM / MKM105PVMoutdoorMKM Series — Multi-Split (DC Inverter)Class 60 — kW figure not stated in the official Daikin brochure.FTKM60PVMMKM-0520-C
MKM95PVM / MKM105PVMoutdoorMKM Series — Multi-Split (DC Inverter)Class 71 — kW figure not stated in the official Daikin brochure.FTKM71PVMMKM-0520-C
RC100AV1MoutdoorFHC-A Series — Ceiling Suspended (Non-Inverter)Class 100 — kW figure not stated in the official Daikin brochure.FHC100AV1MRC-0821-G
RC100AV1MoutdoorFDMC-A Series — Ceiling Concealed Duct (Non-Inverter)Class 100 — kW figure not stated in the official Daikin brochure.FDMC100AV1MRC-0821-G
RC100BV1MoutdoorFCC-A Series — Ceiling CassetteNot stated in the official Daikin brochure.FCC100AV1M8RC-0921-H
RC100BY1M / RC100AGY1MoutdoorFVC-A Series — Floor Standing36,000 Btu/hFVC100AV1MFVC-0425-C
RC125AY1MoutdoorFHC-A Series — Ceiling Suspended (Non-Inverter)Class 125 — kW figure not stated in the official Daikin brochure.FHC125AV1MRC-0821-G
RC125AY1MoutdoorFDMC-A Series — Ceiling Concealed Duct (Non-Inverter)Class 125 — kW figure not stated in the official Daikin brochure.FDMC125AV1MRC-0821-G
RC125BY1MoutdoorFCC-A Series — Ceiling CassetteNot stated in the official Daikin brochure.FCC125AV1M8RC-0921-H
RC125BY1M9 / RC125AGY1M9outdoorFVC-A Series — Floor Standing42,000 Btu/hFVC125AV1MFVC-0425-C
RC140AY1MoutdoorFHC-A Series — Ceiling Suspended (Non-Inverter)Class 140 — kW figure not stated in the official Daikin brochure.FHC140AV1MRC-0821-G
RC140AY1MoutdoorFDMC-A Series — Ceiling Concealed Duct (Non-Inverter)Class 140 — kW figure not stated in the official Daikin brochure.FDMC140AV1MRC-0821-G
RC140BY1MoutdoorFCC-A Series — Ceiling CassetteNot stated in the official Daikin brochure.FCC140AV1M8RC-0921-H
RC140BY1M9 / RC140AGY1M9outdoorFVC-A Series — Floor Standing48,000 (full 4TR) Btu/hFVC140AV1MFVC-0425-C
RC160AY1MoutdoorFHC-A Series — Ceiling Suspended (Non-Inverter)Class 160 — kW figure not stated in the official Daikin brochure.FHC160AV1MRC-0821-G
RC160AY1MoutdoorFDMC-A Series — Ceiling Concealed Duct (Non-Inverter)Class 160 — kW figure not stated in the official Daikin brochure.FDMC160AV1MRC-0821-G
RC25AV1MoutdoorFDMC-A Series — Ceiling Concealed Duct (Non-Inverter)Class 25 — kW figure not stated in the official Daikin brochure.FDBC25AV1MRC-0821-G
RC35AV1MoutdoorFDMC-A Series — Ceiling Concealed Duct (Non-Inverter)Class 35 — kW figure not stated in the official Daikin brochure.FDBC35AV1MRC-0821-G
RC50AV1MoutdoorFHC-A Series — Ceiling Suspended (Non-Inverter)Class 50 — kW figure not stated in the official Daikin brochure.FHC50AV1MRC-0821-G
RC50AV1MoutdoorFDMC-A Series — Ceiling Concealed Duct (Non-Inverter)Class 50 — kW figure not stated in the official Daikin brochure.FDMC50AV1MRC-0821-G
RC50BV1MoutdoorFCC-A Series — Ceiling CassetteNot stated in the official Daikin brochure.FCC50AV1M8RC-0921-H
RC60AV1MoutdoorFHC-A Series — Ceiling Suspended (Non-Inverter)Class 60 — kW figure not stated in the official Daikin brochure.FHC60AV1MRC-0821-G
RC60AV1MoutdoorFDMC-A Series — Ceiling Concealed Duct (Non-Inverter)Class 60 — kW figure not stated in the official Daikin brochure.FDMC60AV1MRC-0821-G
RC60BV1MoutdoorFCC-A Series — Ceiling CassetteNot stated in the official Daikin brochure.FCC60AV1M8RC-0921-H
RC85AV1MoutdoorFHC-A Series — Ceiling Suspended (Non-Inverter)Class 85 — kW figure not stated in the official Daikin brochure.FHC85AV1MRC-0821-G
RC85AV1MoutdoorFDMC-A Series — Ceiling Concealed Duct (Non-Inverter)Class 85 — kW figure not stated in the official Daikin brochure.FDMC85AV1MRC-0821-G
RC85BV1MoutdoorFTV-P Series30,000 Btu/hFTV85PBV1MFTV-0724-T
RC85BV1MoutdoorFCC-A Series — Ceiling CassetteNot stated in the official Daikin brochure.FCC85AV1M8RC-0921-H
RC85BY1M / RC85AGY1MoutdoorFVC-A Series — Floor Standing29,000 Btu/hFVC85AV1M9FVC-0425-C
RGFV100AV1MoutdoorFCFV Series — Ceiling Cassette (Non-Inverter)Class 100 — kW figure not stated in the official Daikin brochure.FCFV100AV1MFFCFV-1221-A
RGFV125AY1MoutdoorFCFV Series — Ceiling Cassette (Non-Inverter)Class 125 — kW figure not stated in the official Daikin brochure.FCFV125AV1MFFCFV-1221-A
RGFV18AV1SoutdoorFCFV Series — Ceiling Cassette (Non-Inverter)Class 18 — kW figure not stated in the official Daikin brochure.FCFV18AV1SFCFV-1221-A
RGFV24AV1SoutdoorFCFV Series — Ceiling Cassette (Non-Inverter)Class 24 — kW figure not stated in the official Daikin brochure.FCFV24AV1SFCFV-1221-A
RGFV30AV1SoutdoorFCFV Series — Ceiling Cassette (Non-Inverter)Class 30 — kW figure not stated in the official Daikin brochure.FCFV30AV1SFCFV-1221-A
RGFV36AV1SoutdoorFCFV Series — Ceiling Cassette (Non-Inverter)Class 36 — kW figure not stated in the official Daikin brochure.FCFV36AV1SFCFV-1221-A
RGFV42AY1SoutdoorFCFV Series — Ceiling Cassette (Non-Inverter)Class 42 — kW figure not stated in the official Daikin brochure.FCFV42AV1SFCFV-1221-A
RGFV46AY1SoutdoorFCFV Series — Ceiling Cassette (Non-Inverter)Class 46 — kW figure not stated in the official Daikin brochure.FCFV46AV1SFCFV-1221-A
RGFV50AV1MoutdoorFCFV Series — Ceiling Cassette (Non-Inverter)Class 50 — kW figure not stated in the official Daikin brochure.FCFV50AV1MFFCFV-1221-A
RGFV60AV1MoutdoorFCFV Series — Ceiling Cassette (Non-Inverter)Class 60 — kW figure not stated in the official Daikin brochure.FCFV60AV1MFFCFV-1221-A
RGFV85AV1MoutdoorFCFV Series — Ceiling Cassette (Non-Inverter)Class 85 — kW figure not stated in the official Daikin brochure.FCFV85AV1MFFCFV-1221-A
RKB25AV1MoutdoorFTKB Series9,000 (3,500 - 9,200) Btu/hFTKB25AV1MFTKB-1225-A
RKB35AV1MoutdoorFTKB Series12,300 (4,100 - 12,800) Btu/hFTKB35AV1MFTKB-1225-A
RKB50AV1MoutdoorFTKB Series18,000 (5,600 - 18,500) Btu/hFTKB50AV1MFTKB-1225-A
RKB71AV1MoutdoorFTKB Series24,000 (6,600 - 24,500) Btu/hFTKB71AV1MFTKB-1225-A
RKB75AV1MoutdoorFTKB Series25,600 (7,900 - 29,000) Btu/hFTKB75AV1MFTKB-1225-A
RKE25AV1MoutdoorFTKE Series9,000 (3,500 - 9,200) Btu/hFTKE25AV1MFTKE-0724-A
RKE35AV1MoutdoorFTKE Series12,300 (4,100 - 12,800) Btu/hFTKE35AV1MFTKE-0724-A
RKE50AV1MoutdoorFTKE Series18,000 (5,200 - 18,500) Btu/hFTKE50AV1MFTKE-0724-A
RKE71AV1MoutdoorFTKE Series24,000 (6,600 - 24,500) Btu/hFTKE71AV1MFTKE-0724-A
RKF25CV1M9outdoorFTKF Series9,000 (3,400 - 9,200) Btu/hFTKF25CV1MFTKF-0824-J
RKF35CV1MoutdoorFTKF Series12,300 (4,100 - 13,000) Btu/hFTKF35CV1MFTKF-0824-J
RKF50CV1MoutdoorFTKF Series18,000 (5,200 - 18,500) Btu/hFTKF50CV1MFTKF-0824-J
RKF71CV1MoutdoorFTKF Series24,000 (6,600 - 24,500) Btu/hFTKF71CV1MFTKF-0824-J
RKF75CV1MoutdoorFTKF Series25,600 (7,900 - 29,000) Btu/hFTKF75CV1MFTKF-0824-J
RKM25TVMMoutdoorFTKM Series8,500 (4,100 - 12,300) Btu/hFTKM25TVMMFTKM-0323-D-L
RKM35TVMMoutdoorFTKM Series11,900 (4,100 - 14,000) Btu/hFTKM35TVMMFTKM-0323-D-L
RKM50TVMMoutdoorFTKM Series17,700 (4,100 - 21,200) Btu/hFTKM50TVMMFTKM-0323-D-L
RKM60TVMMoutdoorFTKM Series20,500 (4,100 - 24,200) Btu/hFTKM60TVMMFTKM-0323-D-L
RKM71TVMMoutdoorFTKM Series24,200 (4,100 - 28,000) Btu/hFTKM71TVMMFTKM-0323-D-L
RKP28AV1M9outdoorFTKP Series9,500 (3,400 - 11,000) Btu/hFTKP28AV1MFTKP-0824-F
RKP35AV1MoutdoorFTKP Series12,300 (4,100 - 13,000) Btu/hFTKP35AV1MFTKP-0824-F
RKP50AV1MoutdoorFTKP Series19,000 (6,000 - 21,200) Btu/hFTKP50AV1MFTKP-0824-F
RKP71AV1MoutdoorFTKP Series24,000 (6,600 - 24,500) Btu/hFTKP71AV1MFTKP-0824-F
RKU28BV1MoutdoorFTKH Series — Smarto9,700 (3,700 - 11,600) Btu/hFTKH28BV1MFFTKH-0426-M
RKU35BV1MoutdoorFTKH Series — Smarto12,100 (4,000 - 13,000) Btu/hFTKH35BV1MFFTKH-0426-M
RKU50BV1MoutdoorFTKH Series — Smarto19,000 (6,000 - 21,200) Btu/hFTKH50BV1MFFTKH-0426-M
RV28PBV1M9outdoorFTV-P Series9,500 Btu/hFTV28PBV1MFTV-0724-T
RV35PBV1M9outdoorFTV-P Series12,000 Btu/hFTV35PBV1MFTV-0724-T
RV50PBV1MoutdoorFTV-P Series18,000 Btu/hFTV50PBV1MFTV-0724-T
RV60PBV1MoutdoorFTV-P Series22,500 Btu/hFTV60PBV1MFTV-0724-T
RXQ10BYMoutdoorVRV 6 A Series — Outdoor95,500 Btu/hVRV-1025-K
RXQ12BYMoutdoorVRV 6 A Series — Outdoor114,000 Btu/hVRV-1025-K
RXQ14BYMoutdoorVRV 6 A Series — Outdoor136,000 Btu/hVRV-1025-K
RXQ16BYMoutdoorVRV 6 A Series — Outdoor154,000 Btu/hVRV-1025-K
RXQ18BYMoutdoorVRV 6 A Series — Outdoor171,000 Btu/hVRV-1025-K
RXQ20BYMoutdoorVRV 6 A Series — Outdoor191,000 Btu/hVRV-1025-K
RXQ22BYMoutdoorVRV 6 A Series — Outdoor210,000 Btu/hVRV-1025-K
RXQ24BYMoutdoorVRV 6 A Series — Outdoor229,000 Btu/hVRV-1025-K
RXQ26BYMoutdoorVRV 6 A Series — Outdoor249,000 Btu/hVRV-1025-K
RXQ28BYMoutdoorVRV 6 A Series — Outdoor268,000 Btu/hVRV-1025-K
RXQ30BYMoutdoorVRV 6 A Series — Outdoor285,000 Btu/hVRV-1025-K
RXQ32BYMoutdoorVRV 6 A Series — Outdoor305,000 Btu/hVRV-1025-K
RXQ34BYMoutdoorVRV 6 A Series — Outdoor324,000 Btu/hVRV-1025-K
RXQ36BYMoutdoorVRV 6 A Series — Outdoor341,000 Btu/hVRV-1025-K
RXQ38BYMoutdoorVRV 6 A Series — Outdoor362,000 Btu/hVRV-1025-K
RXQ40BYMoutdoorVRV 6 A Series — Outdoor382,000 Btu/hVRV-1025-K
RXQ42BYMoutdoorVRV 6 A Series — Outdoor399,000 Btu/hVRV-1025-K
RXQ44BYMoutdoorVRV 6 A Series — Outdoor420,000 Btu/hVRV-1025-K
RXQ46BYMoutdoorVRV 6 A Series — Outdoor440,000 Btu/hVRV-1025-K
RXQ48BYMoutdoorVRV 6 A Series — Outdoor457,000 Btu/hVRV-1025-K
RXQ50BYMoutdoorVRV 6 A Series — Outdoor478,000 Btu/hVRV-1025-K
RXQ52BYMoutdoorVRV 6 A Series — Outdoor498,000 Btu/hVRV-1025-K
RXQ54BYMoutdoorVRV 6 A Series — Outdoor512,000 Btu/hVRV-1025-K
RXQ56BYMoutdoorVRV 6 A Series — Outdoor532,000 Btu/hVRV-1025-K
RXQ58BYMoutdoorVRV 6 A Series — Outdoor553,000 Btu/hVRV-1025-K
RXQ60BYMoutdoorVRV 6 A Series — Outdoor573,000 Btu/hVRV-1025-K
RXQ62BYMoutdoorVRV 6 A Series — Outdoor590,000 Btu/hVRV-1025-K
RXQ64BYMoutdoorVRV 6 A Series — Outdoor611,000 Btu/hVRV-1025-K
RXQ66BYMoutdoorVRV 6 A Series — Outdoor631,000 Btu/hVRV-1025-K
RXQ68BYMoutdoorVRV 6 A Series — Outdoor648,000 Btu/hVRV-1025-K
RXQ70BYMoutdoorVRV 6 A Series — Outdoor669,000 Btu/hVRV-1025-K
RXQ72BYMoutdoorVRV 6 A Series — Outdoor689,000 Btu/hVRV-1025-K
RXQ74BYMoutdoorVRV 6 A Series — Outdoor706,000 Btu/hVRV-1025-K
RXQ76BYMoutdoorVRV 6 A Series — Outdoor727,000 Btu/hVRV-1025-K
RXQ78BYMoutdoorVRV 6 A Series — Outdoor747,000 Btu/hVRV-1025-K
RXQ8BYMoutdoorVRV 6 A Series — Outdoor76,400 Btu/hVRV-1025-K
RXUQ10BYMoutdoorVRV 6 X Series — Outdoor96,000 Btu/hVRV-1025-K
RXUQ12BYMoutdoorVRV 6 X Series — Outdoor114,000 Btu/hVRV-1025-K
RXUQ14BYMoutdoorVRV 6 X Series — Outdoor136,000 Btu/hVRV-1025-K
RXUQ16BYMoutdoorVRV 6 X Series — Outdoor154,000 Btu/hVRV-1025-K
RXUQ18BYMoutdoorVRV 6 X Series — Outdoor171,000 Btu/hVRV-1025-K
RXUQ20BYMoutdoorVRV 6 X Series — Outdoor191,000 Btu/hVRV-1025-K
RXUQ22BYMoutdoorVRV 6 X Series — Outdoor210,000 Btu/hVRV-1025-K
RXUQ24BYMoutdoorVRV 6 X Series — Outdoor229,000 Btu/hVRV-1025-K
RXUQ26BYMoutdoorVRV 6 X Series — Outdoor251,000 Btu/hVRV-1025-K
RXUQ28BYMoutdoorVRV 6 X Series — Outdoor268,000 Btu/hVRV-1025-K
RXUQ30BYMoutdoorVRV 6 X Series — Outdoor285,000 Btu/hVRV-1025-K
RXUQ32BYMoutdoorVRV 6 X Series — Outdoor305,000 Btu/hVRV-1025-K
RXUQ34BYMoutdoorVRV 6 X Series — Outdoor328,000 Btu/hVRV-1025-K
RXUQ36BYMoutdoorVRV 6 X Series — Outdoor345,000 Btu/hVRV-1025-K
RXUQ38BYMoutdoorVRV 6 X Series — Outdoor362,000 Btu/hVRV-1025-K
RXUQ40BYMoutdoorVRV 6 X Series — Outdoor382,000 Btu/hVRV-1025-K
RXUQ42BYMoutdoorVRV 6 X Series — Outdoor399,000 Btu/hVRV-1025-K
RXUQ44BYMoutdoorVRV 6 X Series — Outdoor420,000 Btu/hVRV-1025-K
RXUQ46BYMoutdoorVRV 6 X Series — Outdoor440,000 Btu/hVRV-1025-K
RXUQ48BYMoutdoorVRV 6 X Series — Outdoor457,000 Btu/hVRV-1025-K
RXUQ50BYMoutdoorVRV 6 X Series — Outdoor474,000 Btu/hVRV-1025-K
RXUQ52BYMoutdoorVRV 6 X Series — Outdoor495,000 Btu/hVRV-1025-K
RXUQ54BYMoutdoorVRV 6 X Series — Outdoor519,000 Btu/hVRV-1025-K
RXUQ56BYMoutdoorVRV 6 X Series — Outdoor536,000 Btu/hVRV-1025-K
RXUQ58BYMoutdoorVRV 6 X Series — Outdoor553,000 Btu/hVRV-1025-K
RXUQ60BYMoutdoorVRV 6 X Series — Outdoor573,000 Btu/hVRV-1025-K
RXUQ6BYMoutdoorVRV 6 X Series — Outdoor54,600 Btu/hVRV-1025-K
RXUQ8BYMoutdoorVRV 6 X Series — Outdoor76,400 Btu/hVRV-1025-K
RZF100CVMoutdoorFHA-B Series — Ceiling Suspended (Inverter)Class 100 — kW figure not stated in the official Daikin brochure.FHA100BVMARZF-1217-A
RZF125CVMoutdoorFHA-B Series — Ceiling Suspended (Inverter)Class 125 — kW figure not stated in the official Daikin brochure.FHA125BVMARZF-1217-A
RZF140CVMoutdoorFHA-B Series — Ceiling Suspended (Inverter)Class 140 — kW figure not stated in the official Daikin brochure.FHA140BVMARZF-1217-A
RZF50CVMoutdoorFHA-B Series — Ceiling Suspended (Inverter)Class 50 — kW figure not stated in the official Daikin brochure.FHA50BVMARZF-1217-A
RZF60CVMoutdoorFHA-B Series — Ceiling Suspended (Inverter)Class 60 — kW figure not stated in the official Daikin brochure.FHA60BVMARZF-1217-A
RZF71CoutdoorFHA-B Series — Ceiling Suspended (Inverter)Class 71 — kW figure not stated in the official Daikin brochure.FHA71BVMARZF-1217-A
RZFC100AVMMoutdoorFDMFC-A Series — Ceiling Concealed Duct36,000 (17,100-38,200) Btu/hFDMFC100AV1MRC-0921-H
RZFC100AVMMoutdoorFCFC A-Series — Inverter Ceiling Cassette36,000 (17,100-38,200) Btu/hFCFC100AV1MFRC-0921-H
RZFC125AY1MoutdoorFDMFC-A Series — Ceiling Concealed Duct42,000 (19,500-47,800) Btu/hFDMFC125AV1MRC-0921-H
RZFC125AY1MoutdoorFCFC A-Series — Inverter Ceiling Cassette42,000 (19,500-47,800) Btu/hFCFC125AV1MFRC-0921-H
RZFC140AY1MoutdoorFDMFC-A Series — Ceiling Concealed Duct48,000 (21,200-52,900) Btu/hFDMFC140AV1MRC-0921-H
RZFC140AY1MoutdoorFCFC A-Series — Inverter Ceiling Cassette48,000 (21,200-52,900) Btu/hFCFC140AV1MFRC-0921-H
RZFC50AGVMMoutdoorFDMFC-A Series — Ceiling Concealed Duct18,500 (7,800-19,100) Btu/hFDMFC50AV1MRC-0921-H
RZFC50AGVMMoutdoorFCFC A-Series — Inverter Ceiling Cassette18,500 (7,800-19,100) Btu/hFCFC50AV1MFRC-0921-H
RZFC60AGVMMoutdoorFDMFC-A Series — Ceiling Concealed Duct20,500 (8,900-21,500) Btu/hFDMFC60AV1MRC-0921-H
RZFC60AGVMMoutdoorFCFC A-Series — Inverter Ceiling Cassette20,500 (8,900-21,500) Btu/hFCFC60AV1MFRC-0921-H
RZFC71AGVMMoutdoorFDMFC-A Series — Ceiling Concealed Duct24,200 (10,900-27,300) Btu/hFDMFC71AV1MRC-0921-H
RZFC71AGVMMoutdoorFCFC A-Series — Inverter Ceiling Cassette24,200 (10,900-27,300) Btu/hFCFC71AV1MFRC-0921-H
RZFC85AVMMoutdoorFDMFC-A Series — Ceiling Concealed Duct30,000 (14,300-34,100) Btu/hFDMFC85AV1MRC-0921-H
RZFC85AVMMoutdoorFCFC A-Series — Inverter Ceiling Cassette30,000 (14,300-34,100) Btu/hFCFC85AV1MFRC-0921-H
RZFG100AVMMoutdoorFCFG Series — REVO Max Surround Cassette36,000 (17,100-38,200) Btu/hFCFG100AV1MFFCFG-0825-E
RZFG125AY1MoutdoorFCFG Series — REVO Max Surround Cassette42,000 (19,500-47,800) Btu/hFCFG125AV1MFFCFG-0825-E
RZFG140AY1MoutdoorFCFG Series — REVO Max Surround Cassette48,000 (21,200-52,900) Btu/hFCFG140AV1MFFCFG-0825-E
RZFG50AGVMMoutdoorFCFG Series — REVO Max Surround Cassette18,500 (7,800-19,100) Btu/hFCFG50AV1MF9FCFG-0825-E
RZFG60AGVMMoutdoorFCFG Series — REVO Max Surround Cassette20,500 (8,900-21,500) Btu/hFCFG60AV1MF9FCFG-0825-E
RZFG71AGVMMoutdoorFCFG Series — REVO Max Surround Cassette24,200 (10,900-27,300) Btu/hFCFG71AV1MF9FCFG-0825-E
RZFG85AVMMoutdoorFCFG Series — REVO Max Surround Cassette30,000 (14,300-34,100) Btu/hFCFG85AV1MF9FCFG-0825-E

Send us your floor plan.

We will size the system, name the Daikin model and quote it. Daikin publishes the catalogue; choosing from it is the part we are for.

Included
Heat load and capacity sizing
Included
Model selection against your plan
Included
Site survey and commercial consultation
Included
Written quotation

About these specifications

Every figure is transcribed from an official Daikin Malaysia brochure, and each series states the document code and revision it came from. Where a brochure does not publish a figure, this page says so rather than estimating it. Daikin revises specifications without notice — for anything a design or a tender will rely on, open Daikin's own current document from the links above.

Chance Air-Cond Sales & Service Sdn. Bhd. is an authorised Daikin dealer and has been a Daikin Million Dollar Dealer for six consecutive years. More about the company