USJ Bungalow — Whole-House VRV, Delivered Inside a Designer's Programme

Whole-house multi-zone VRV that had to stay invisible within the interior scheme and fit a design programme already in motion.

Client

A private bungalow in USJ, Subang Jaya, delivered with the project's appointed interior design firm.

Challenge

A designer-led bungalow project puts HVAC in a supporting role with hard constraints: the system must deliver whole-house comfort with independent room control, while staying invisible within the interior scheme and coordinating with a design programme already in motion.

Equipment placement, ceiling void routing and outdoor unit siting all have to be resolved against the designer's intent rather than imposed on it.

Solution

A Daikin VRV system providing multi-zone control from consolidated outdoor plant — the appropriate architecture for a large residence where rooms are used at different times and each needs independent setting, and where minimising visible outdoor equipment matters to the design.

CASS worked to the designer's drawings and programme, handling equipment selection, routing coordination, and site sequencing around other trades.

Execution

Full VRV installation including outdoor and indoor plant, Y-joint refrigerant branching, copper and insulation, SIRIM-certified wiring, and crane mobilisation for outdoor unit placement.

Evidence

  • Designer-led premium residential project — VRV, whole-house multi-zone
  • Delivered as HVAC partner to the project's appointed interior design firm
  • Coordination to designer drawings and programme
  • Crane-assisted outdoor plant installation

Outcome

A completed bungalow VRV installation delivered within a designer-led programme — the model for CASS's interior-designer channel.

On site

  • A ceiling cassette set into a plasterboard ceiling during fit-out, joints still unfinished.
    Cassette in position before the ceiling was finished
  • A ceiling cassette installed within a coffered ceiling detail, control wiring still exposed.
    Set into the designer's coffer detail rather than imposed on it
  • A wall-mounted indoor unit fitted high on a bedroom wall during the renovation phase.
    Wall unit where the ceiling void could not take a cassette
  • Insulated refrigerant lines and control cabling run across a flat roof toward the outdoor plant.
    Refrigerant and control runs to the roof plant
  • Three VRV condensing units installed side by side on a flat roof deck beneath a shade canopy.
    Consolidated outdoor plant, sited to stay out of the designed elevations

This project was delivered under HVAC Design & Build.